Corrective force analysis for scoliosis from implant rod deformation.
نویسندگان
چکیده
BACKGROUND Scoliosis is a serious disease in which a human spine is abnormally deformed in three dimensions with vertebral rotation. Surgical treatment is attained when the scoliotic spine is corrected into its normal shape by implant rods and screws fixed into the vertebrae. The three-dimensional corrective forces acting at the screws deformed the implant rod during the surgical treatment of scoliosis. The objective of this study was to propose a method to analyze the three-dimensional forces acting at the rod using the changes of implant rod geometry before and after the surgical treatment. METHODS An inverse method based on Finite Element Analysis is proposed. The geometries of implant rod before and after the surgical treatment were measured three dimensionally. The implant rod before the surgical treatment was reconstructed using an elasto-plastic finite element model. The three-dimensional forces were applied iteratively to the rod through the screws such that the rod is deformed the same after the surgical treatment of scoliosis. FINDINGS The maximum force acting at the screw of each patient ranged from 198N to 439N. The magnitude of forces was clinically acceptable. The maximum forces occurred at the lowest fixation level of vertebra of each patient. INTERPRETATION The three-dimensional forces distribution that deformed the rod can be evaluated using the changes of implant geometry. Although the current clinical cases are still few, this study demonstrated the feasibility of measuring the forces that deformed the implant rod after the surgical treatment of scoliosis.
منابع مشابه
Scoliosis corrective force estimation from the implanted rod deformation using 3D-FEM analysis
BACKGROUND Improvement of material property in spinal instrumentation has brought better deformity correction in scoliosis surgery in recent years. The increase of mechanical strength in instruments directly means the increase of force, which acts on bone-implant interface during scoliosis surgery. However, the actual correction force during the correction maneuver and safety margin of pull out...
متن کاملEffects of Multilevel Facetectomy and Screw Density on Postoperative Changes in Spinal Rod Contour in Thoracic Adolescent Idiopathic Scoliosis Surgery
Flattening of the preimplantation rod contour in the sagittal plane influences thoracic kyphosis (TK) restoration in adolescent idiopathic scoliosis (AIS) surgery. The effects of multilevel facetectomy and screw density on postoperative changes in spinal rod contour have not been documented. This study aimed to evaluate the effects of multilevel facetectomy and screw density on changes in spina...
متن کاملAn FE investigation simulating intra-operative corrective forces applied to correct scoliosis deformity
BACKGROUND Adolescent idiopathic scoliosis (AIS) is a deformity of the spine, which may require surgical correction by attaching a rod to the patient's spine using screws implanted in the vertebral bodies. Surgeons achieve an intra-operative reduction in the deformity by applying compressive forces across the intervertebral disc spaces while they secure the rod to the vertebra. We were interest...
متن کاملImplant Failure of Titanium Versus Cobalt-Chromium Growing Rods in Early-onset Scoliosis.
STUDY DESIGN Retrospective case series of one institute database. OBJECTIVE To investigate the differences in the metallic strength of rods used for implant failure in the dual growing rod technique and evaluate clinical outcomes. SUMMARY OF BACKGROUND DATA The dual growing rod technique in which implanted rods extend with the growth of the spine is a useful treatment for early onset scolio...
متن کاملOptimum Die Design in Drawing of Square Section Rod from Round Bar
Drawing of square section rod from round bar can be done with two die shapes. In the first die shape, deformation starts from corners of the square and in second die shape, deformation starts from sides of square. This article has compared the drawing force for both die shapes and as a result optimum die shape was determined. Due to complexity of metal flow inside the die, analyzing of actual p...