Simple Automated Method for Urinary Creatinine Estimation.
نویسندگان
چکیده
The increasing numbers of investigations into metabolic processes have necessitated the adaptation to automated principles of a method whereby the efficacy of quantitative urine collections can be tested. The estimation of creatinine (creatine anhydride) for this purpose has several aJvantages over other methods which have been used. Creatinine excretion is fairly constant from day to day (Folin, 1914; Shaffer, 1914), being independent of muscular activity, urine volume, and the state of nitrogen metabolism of the body. Creatinine is a waste product endogenously derived from creatine and its level of excretion is influenced by the diet only when the diet contains significant quantities of creatine or creatinine, for example, in a heavy fish or meat meal. When preformed creatinine is administered to normal subjects it is rapidly and almost wholly excreted. Thus, it can be seen that if marked variations in urinary creatinine levels are observed which do not correspond to muscular development or breakdown, or to changes in the diet involving preformed creatinine, it can be assumed that there has been some error in the collection of urine specimens. The main criteria of the method for urinary creatinine estimation were that it should be rapid, accurate, and basically simple in both design and operation. The method which has been evolved is operated at a rate of 60 estimations per hour, can estimate specimens containing creatinine concentrations of 0-200 mg./100 ml., and is based on the Jaffe (1886) reaction. The Jaffe reaction takes place when creatinine is mixed with alkaline picrate solution giving rise to the formation of the red tautomer of creatinine picrate (Greenwald and Gross, 1924; Greenwald, 1925, 1928). The known lack of specificity of the reaction for plasma has not been held to invalidate its use in urine estimations. The coloured product formed obeys Beer's law for monochromatic
منابع مشابه
Urinary C-peptide and Urine C-peptide/creatinine Ratio (ucpcr) Are Possible Predictors of Endogenous Insulin Secretion in T2dm Subjects - a Randomized Study
Estimation of serum C-peptide (SCP) is used as a measure of endogenous insulin secretion in type 2 diabetes mellitus (T2DM). Urinary CPeptide (UCP) and urinary C-Peptide creatinine ratio (UCPCR) are non invasive, simple and easily reproducible tests which may be considered as an alternative for SCP. In our study we estimated fasting serum C-peptide, urinary C-peptide and UCPCR in Type 2 Diabete...
متن کاملCorrelation between cystatin C-based formulas, Schwartz formula and urinary creatinine clearance for glomerular filtration rate estimation in children with kidney disease
INTRODUCTION Assessment of glomerular filtration rate (GFR) is an important tool for monitoring renal function. OBJECTIVES Regarding to limitations in available methods, we intended to calculate GFR by cystatin C (Cys C) based formulas and determine correlation rate of them with current methods. PATIENTS AND METHODS We studied 72 children (38 boys and 34 girls) with renal disorders. The 24 ...
متن کاملMarked variation in creatinine clearance estimation in patients receiving parenteral nutrition.
Amin A. Nanji, Division of Clinical Chemistry, Vancouver General Hospital, Vancouver V5Z1M9 (Canada) Dear Sir, Analytical and biologic variations in serum and urinary creatinine may account for up to 33% variability in creatinine clearance calculations [1]. We wish to report on the marked variability of creatinine clearance in patients receiving total parenteral nutrition (TPN). 18 of 93 patien...
متن کاملA Novel Method for Automated Estimation of Effective Parameters of Complex Auditory Brainstem Response: Adaptive Processing based on Correntropy Concept
Objectives: Automated Auditory Brainstem Responses (ABR) peak detection is a novel technique to facilitate the measurement of neural synchrony along the auditory pathway through the brainstem. Analyzing the location of the peaks in these signals and the time interval between them may be utilized either for analyzing the hearing process or detecting peripheral and central lesions in the human he...
متن کاملAutomated determination of urinary creatinine without sample dilution: theory and practice.
The rate of the Jaffé reaction depends on the concentration of sodium hydroxide; the pseudo-first-order rate constant of the reaction, at 37 degrees C in 10 mmol/L picrate solution, is 0.004 mmol/L. We formulated an automated method to determine urinary creatinine directly without manual sample dilution. The conditions are as follows: 10 mmol/L picrate and 60 mmol/L sodium hydroxide (final conc...