Biomechanical effect of rotator cuff augmentation with an acellular dermal matrix graft: a cadaver study.

نویسندگان

  • Hiromichi Omae
  • Scott P Steinmann
  • Chunfeng Zhao
  • Mark E Zobitz
  • Prasit Wongtriratanachai
  • John W Sperling
  • Kai-Nan An
چکیده

BACKGROUND Acellular human dermal matrix grafts (Graftjacket; Wright Medical Technology, Arlington, TN, USA) are used clinically for rotator cuff augmentation without a detailed understanding of their biomechanical effects. The purpose of this study was to evaluate the effect of augmentation with dermal grafts on the biomechanical effects of rotator cuff repairs. METHODS Nine matched pairs of human cadaveric shoulders were used. A single-row rotator cuff repair combined with an augmentation graft was performed on one shoulder, and a single-row repair was performed on the contralateral shoulder as a control. An acellular dermal matrix graft was sutured to the tendon medially and fixed to the humerus laterally. The constructs were preloaded at 10 N and then cyclically loaded between 10 and 180 N for 1000 cycles, followed by tensile testing to failure at 1.0 mm/s. FINDINGS The maximum load of the augmentation group (560.2 N, SD 95.5) was greater than that of the control group (345.7 N, SD 60.8), while the linear stiffness of the augmentation group (65.2 N/mm, SD 15.6) was less than that of the control group (77.2 N/mm, SD 15.7). Reliable gap distance data were not obtained during cyclic loading in 5 of 9 augmented repairs due to the elasticity of the dermal matrix graft. INTERPRETATION The dermal matrix graft augmentation increased the maximum load but did not increase the linear stiffness. The elasticity of the dermal matrix graft affected the biomechanical effects of the augmented rotator cuff repairs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical analysis of rotator cuff repairs with extracellular matrix graft augmentation.

Despite advances in surgical techniques, 20% to 90% of rotator cuff (RTC) repairs fail. They tend to fail at the suture-tendon junction due to tension at the repair and gap formation prior to healing. This study evaluated the gap formation and ultimate tensile failure loads of a RTC repair with a decellularized human dermal allograft. Augmentation of a RTC repair with an extracellular matrix gr...

متن کامل

Preliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix

 Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...

متن کامل

A prospective, randomized evaluation of acellular human dermal matrix augmentation for arthroscopic rotator cuff repair.

PURPOSE To prospectively evaluate the safety and effectiveness of arthroscopic acellular human dermal matrix augmentation of large rotator cuff tear repairs. METHODS A prospective, institutional review board-approved, multicenter series of patients undergoing arthroscopic repair of 2-tendon rotator cuff tears measuring greater than 3 cm were randomized by sealed envelopes opened at the time o...

متن کامل

Latissimus Dorsi Tendon Transfer with GraftJacket® Augmentation to Increase Tendon Length for an Irreparable Rotator Cuff Tear

Massive irreparable rotator cuff tears can be reconstructed with latissimus dorsi tendon transfers (LDTT). Although uncommon, the natural length of the latissimus dorsi tendon (LDT) could be insufficient for transfer even after adequate soft tissue releases. Descriptions of cases where grafts were needed to lengthen the LDT are therefore rare. We located only two reports of the use of an acellu...

متن کامل

Mini-Open Suture Bridge Repair with Porcine Dermal Patch Augmentation for Massive Rotator Cuff Tear: Surgical Technique and Preliminary Results

BACKGROUND The aim of this study was to describe the mini-open suture bridge technique with porcine dermal patch augmentation for massive rotator cuff tear and to assess preliminary clinical and radiological results. METHODS Five patients with massive rotator cuff tear for which it was not possible to restore the anatomical footprint underwent mini-open suture bridge repair using a porcine de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical biomechanics

دوره 27 8  شماره 

صفحات  -

تاریخ انتشار 2012