Low-Dose Volume-of-Interest C-Arm CT Imaging of Intracranial Stents and Flow Diverters.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Volume-of-interest C-arm CT is a novel technique for imaging of intracranial high-contrast objects. We performed this study to evaluate the potential diagnostic value and radiation dose reduction of this technique for imaging of intracranial stents and flow diverters. MATERIALS AND METHODS Twenty-seven patients were imaged with a VOI C-arm CT scan following treatment with a flow diverter or stent-assisted coiling. The radiation dose-area product was recorded for VOI scans. For comparison, the dose-area product from 30 previously acquired consecutive full-view DynaCTs was used. Thermoluminescence dosimetry by using 35 evenly distributed thermoluminescence dosimeters in an anthropomorphic head phantom was also performed by using both conventional full field and VOI acquisitions. Three observers were presented with VOI images for assessment of the potential diagnostic value. RESULTS The dose-area product measurements showed an exposure reduction of 85% compared with the full field acquisitions used for comparison. The thermoluminescence dosimetry evaluations also showed a considerable dose reduction of 79.8% throughout the volume. For most of the evaluated cases, the observers thought that diagnostically useful information was provided by the VOI images (α = .810). Visualization of device details, such as the extent of opening, positioning, wall apposition, and aneurysm coverage, was judged of good diagnostic quality for most cases (88.9%-92.6%). CONCLUSIONS In this study, VOI C-arm CT provided high-quality diagnostic images of intracranial stents and flow diverters at a dramatic reduction of radiation exposure. Image content was thought to add useful information. It is a promising method to assess device status during procedures and at follow-up.
منابع مشابه
The Added Value of Volume-of-Interest C-Arm CT Imaging during Endovascular Treatment of Intracranial Aneurysms.
BACKGROUND AND PURPOSE Successful endovascular treatment of intracranial aneurysms requires understanding the exact relationship of implanted devices to the aneurysm, parent artery, and other branch vessels during the treatment. Intraprocedural C-arm CT imaging has been shown to provide such information. However, its repeated use is limited due to increasing radiation exposure to the patient. T...
متن کاملFlow diverter stents in the treatment of intracranial aneurysms: Where are we?
Flow diverter stents are devices designed to treat complex aneurysms. According to preliminary series published in the literature, treatment of aneurysms with flow diverters is highly efficacious with acceptable morbidity and mortality. Delayed aneurysm ruptures have been reported but mechanisms are actually not completely elucidated. In-stent thrombosis or stenosis was also observed. Indicatio...
متن کاملAnalysis of neointima development in flow diverters using optical coherence tomography imaging
BACKGROUND Flow diverters are used for the treatment of intracranial aneurysms. Surface modification may decrease the thrombogenicity of flow diverters but the details are unknown. Optical coherence tomography (OCT) is an intravascular imaging test with high resolution which identifies neointimal growth over stents. We compared the development of neointima in a flow diverter and stents with and...
متن کاملQuantitative Computed Tomographic Volumetry after Treatment of a Giant Intracranial Aneurysm with a Pipeline Embolization Device
Recently developed flow diverters, such as the pipeline embolization device (PED), allow for safe and efficacious treatment of giant intracranial aneurysms, with high occlusion rates and a low incidence of complications. However, incomplete obliteration after PED treatment may lead to aneurysm regrowth and delayed rupture. Herein, we report a case of a partially thrombosed giant aneurysm of the...
متن کاملIntravenous C-Arm Conebeam CT Angiography following Long-Term Flow-Diverter Implantation: Technologic Evaluation and Preliminary Results.
BACKGROUND AND PURPOSE A noninvasive investigation with high spatial resolution and without metal artifacts is necessary for long-term imaging follow-up after flow-diverter implantation. We aimed to evaluate the diagnostic value of conebeam CT angiography with intravenous contrast enhancement in the assessment of vascular status following implantation of the Pipeline Embolization Device and to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 37 4 شماره
صفحات -
تاریخ انتشار 2016