Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda

نویسندگان

  • Heidi Hopkins
  • Iveth J. González
  • Spencer D. Polley
  • Patrick Angutoko
  • John Ategeka
  • Caroline Asiimwe
  • Bosco Agaba
  • Daniel J. Kyabayinze
  • Colin J. Sutherland
  • Mark D. Perkins
  • David Bell
چکیده

BACKGROUND Current malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too complex for field deployment. A new commercial molecular assay based on loop-mediated isothermal amplification (LAMP) was assessed for field use. METHODS Malaria LAMP (Eiken Chemical, Japan) was evaluated for samples from 272 outpatients at a rural Ugandan clinic and compared with expert microscopy, nested PCR, and quantitative PCR (qPCR). Two technicians performed the assay after 3 days of training, using 2 alternative blood sample-preparation methods and visual interpretation of results by fluorescence assay. RESULTS Compared with 3-well nested PCR, the sensitivity of both LAMP and single-well nested PCR was 90%; the microscopy sensitivity was 51%. For samples with a Plasmodium falciparum qPCR titer of ≥ 2 parasites/µL, LAMP sensitivity was 97.8% (95% confidence interval, 93.7%-99.5%). Most false-negative LAMP results involved samples with parasitemia levels detectable by 3-well nested PCR but very low or undetectable by qPCR. CONCLUSIONS Malaria LAMP in a remote Ugandan clinic achieved sensitivity similar to that of single-well nested PCR in a United Kingdom reference laboratory. LAMP dramatically lowers the detection threshold achievable in malaria-endemic settings, providing a new tool for diagnosis, surveillance, and screening in elimination strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Loop Mediated Isothermal DNA Amplification (LAMP) Kit for Malaria Diagnosis in P. vivax Endemic Settings of Colombia

BACKGROUND Most commonly used malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections which are frequent in low transmission settings. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too laborious for field deployment. In this study, the applicability of a malaria diagnosis kit base...

متن کامل

A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2

Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...

متن کامل

Loop-mediated isothermal amplification assay for rapid diagnosis of malaria infections in an area of endemicity in Thailand.

The loop-mediated isothermal amplification (LAMP) method, developed by our group for diagnosis of four human malaria parasites, was evaluated on a large scale at a remote clinic in Thailand where malaria is endemic. A total of 899 febrile patients were analyzed in this study. LAMP was first evaluated in 219 patients, and the result was compared to those of two histidine-rich protein (HRP)-2 rap...

متن کامل

Loop-Mediated Isothermal Amplification Assay for Identification of Five Human Plasmodium Species in Malaysia

The lack of rapid, affordable, and accurate diagnostic tests represents the primary hurdle affecting malaria surveillance in resource- and expertise-limited areas. Loop-mediated isothermal amplification (LAMP) is a sensitive, rapid, and cheap diagnostic method. Five species-specific LAMP assays were developed based on 18S rRNA gene. Sensitivity and specificity of LAMP results were calculated as...

متن کامل

Loop-mediated isothermal amplification (RT-LAMP): a new approach for the detection of foot-and-mouth disease virus and its sero-types in Pakistan

Successful disease management requires a rapid and sensitive diagnosis method that can recognize early infection even before the manifestation of its clinical signs. The only available field diagnostic tests for foot-and-mouth disease (FMD) are lateral flow devices, commonly known as chromatographic strips. Low sensitivity and inability to detect FMD virus (FMDV) at the serotype level are limit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 208  شماره 

صفحات  -

تاریخ انتشار 2013