Transitional flow at the venous anastomosis of an arteriovenous graft: potential activation of the ERK1/2 mechanotransduction pathway.
نویسندگان
چکیده
We present experimental and computational results that describe the level, distribution, and importance of velocity fluctuations within the venous anastomosis of an arteriovenous graft. The motivation of this work is to understand better the importance of biomechanical forces in the development of intimal hyperplasia within these grafts. Steady-flow in vitro studies (Re = 1060 and 1820) were conducted within a graft model that represents the venous anastomosis to measure velocity by means of laser Doppler anemometry. Numerical simulations with the same geometry and flow conditions were conducted by employing the spectral element technique. As flow enters the vein from the graft, the velocity field exhibits flow separation and coherent structures (weak turbulence) that originate from the separation shear layer. We also report results of a porcine animal study in which the distribution and magnitude of vein-wall vibration on the venous anastomosis were measured at the time of graft construction. Preliminary molecular biology studies indicate elevated activity levels of the extracellular regulatory kinase ERK1/2, a mitogen-activated protein kinase involved in mechanotransduction, at regions of increased vein-wall vibration. These findings suggest a potential relationship between the associated turbulence-induced vein-wall vibration and the development of intimal hyperplasia in arteriovenous grafts. Further research is necessary, however, in order to determine if a correlation exists and to differentiate the vibration effect from that of flow related effects.
منابع مشابه
Flow Field Characterization inside an Arteriovenous Graft- To-vein Anastomosis under Pulsatile Flow Conditions
The purpose of this study was to investigate the relationship between the distribution of turbulence intensity and the localization of stenoses inside the venous anastomosis of arteriovenous (A-V) grafts. Turbulent flow measurements were conducted inside an upscaled end-to-side graft model under pulsatile flow condition. The pulsatile flow waveforms had maximum, minimum and mean Reynolds number...
متن کاملComparison of the Graft Angles Effects on the Temporal Wall Shear Stress Gradients in the Aorto-Coronary and Coronary-Coronary Bypasses
In this theoretical study, the effect of various types of bypass graft angles on the flow field, has been investigated specially on the temporal Wall Shear Stress (WSS) on the toe, heel and some locations on the bed of the Left Anterior Descending (LAD) artery at the anastomoses areas in the Aorto-Coronary (AC) and Coronary-Coronary (CC) bypasses. Flow fields in both bypasses with angles of...
متن کاملSirolimus-eluting stents to abolish intimal hyperplasia and improve flow in porcine arteriovenous grafts: a 4-week follow-up study.
BACKGROUND The patency of arteriovenous (AV) expanded polytetrafluoroethylene (ePTFE) hemodialysis grafts is severely compromised by intimal hyperplasia (IH) at the venous anastomosis and in the venous outflow tract. We addressed the potential of primary placement of a sirolimus-eluting stent (SES) in a validated porcine model. METHODS AND RESULTS In 25 pigs, ePTFE AV grafts were created bila...
متن کاملNovel paradigms for dialysis vascular access: downstream vascular biology--is there a final common pathway?
Vascular access dysfunction is a major cause of morbidity and mortality in hemodialysis patients. The most common cause of vascular access dysfunction is venous stenosis from neointimal hyperplasia within the perianastomotic region of an arteriovenous fistula and at the graft-vein anastomosis of an arteriovenous graft. There have been few, if any, effective treatments for vascular access dysfun...
متن کاملFlow-induced vein-wall vibration in an arteriovenous graft
The hemodynamic environment of an arteriovenous (AV) graft differs from that of arterial grafts because mean flow rates are typically 10 times greater. This increased flow rate can create a weakly turbulent state, which alters the biomechanical environment greatly and may play a role in AV graft failure. A canine animal study was conducted to simulate the hemodynamic environment of a human AV g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanical engineering
دوره 125 1 شماره
صفحات -
تاریخ انتشار 2003