Right heart function during left heart assist and the effects of volume loading in a canine preparation.

نویسندگان

  • D J Farrar
  • P G Compton
  • H Dajee
  • J D Fonger
  • J D Hill
چکیده

A significant fraction of patients in whom mechanical left ventricular assist devices are implanted for refractory cardiac failure after open heart surgery have had the complication of right heart failure. To evaluate the effects of left ventricular assistance and pressure unloading on right ventricular function, we performed experiments in the normal hearts of open-chest, anesthetized, large mongrel dogs. We compared right ventricular function before and after left ventricular-to-aortic bypass with a roller pump at right atrial pressure levels of 1, 3, 5, and 7 mm Hg produced by volume loading. No significant changes were found in cardiac output or stroke volume over this range of right atrial pressures when comparing that before to that during left ventricular bypass, which at a right atrial pressure of 1 mm Hg reduced peak left ventricular pressure from 96 +/- 6 to 15 +/- 9 mm Hg and at a right atrial pressure of 5 mm Hg reduced it from 113 +/- 3 to 29 +/- 12 mm Hg, while maintaining aortic pressure. There was no evidence of right ventricular failure under these conditions: (from before to during bypass) at a right atrial pressure of 1 mm Hg cardiac output was 3.4 +/- 0.4 to 3.7 +/- 0.6 liter/min and stroke volume was 28 +/- 5 to 33 +/- 6 ml; during volume loading at a right atrial pressure of 7 mm Hg cardiac output was 5.6 +/- 0.6 to 5.7 +/- 0.7 liter/min and stroke volume was 47 +/- 5 to 52 +/- 5 ml.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Dose-volume Analysis of Heart and Lung during 3D Planning of Tangential Breast Cancer Irradiation

Introduction: Breast cancer is becoming more frequently diagnosed at early stages with improved long-term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Materials and Methods: Twenty...

متن کامل

Dose-volume Analysis of Heart and Lung during 3D planning of Tangential Breast Cancer Irradiation

Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive...

متن کامل

LABORATORY INVESTIGATION VENTRICULAR PERFORMANCE Right heart function during left heart assist and the effects of volume loading in a canine preparation

A significant fraction of patients in whom mechanical left ventricular assist devices are implanted for refractory cardiac failure after open heart surgery have had the complication of right heart failure. To evaluate the effects of left ventricular assistance and pressure unloading on right ventricular function, we performed experiments in the normal hearts of open-chest, anesthetized, large m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 70 4  شماره 

صفحات  -

تاریخ انتشار 1984