A New Clinical Instrument for the Early Detection of Cataract Using Dynamic Light Scattering and Corneal Topography

نویسندگان

  • Rafat R. Ansari
  • James F. King
چکیده

A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient’s eye and especially during patient’s repeat visits. This is important because the scattering volume (cross-over region between the scattered light and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Compensation comparison method for assessment of retinal straylight.

PURPOSE Presently, no instrument or method exists that is generally accepted for routine clinical assessment of (functional) retinal straylight. Yet retinal straylight is the cause of major patient complaints, such as hindrance from glare and loss of contrast. It results from disturbances in the optical media that increase light-scattering over angles of 1 degrees to 90 degrees . Its assessment...

متن کامل

Dynamic corneal imaging.

PURPOSE To determine the clinical practicability of in vivo dynamic corneal imaging (DCI) to assess the individual elastic properties of normal human eyes, eyes with abnormal findings, and eyes after refractive surgery. SETTING University Eye Clinic, Paracelsus Private Medical University, Salzburg, Austria. METHODS The DCI method uses sagittal, stepwise, central indentation of the cornea wi...

متن کامل

بررسی آسیب‌های شبکیه به دنبال مصرف کلروکین براساس یافته‌های پریمتری در 52 بیمار مبتلا به آرتریت روماتویید با یافته‌های فوندوسکوپی طبیعی که به بیمارستان اکرم(ص) مراجعه کرده بودند

Chloroquine and its congeners are antimalarial agents which have anti rheumatic properties. One of the most important side effects of these drugs is retinal toxicity. Different methods have been used for early detection of this complication but there is no firm consensus about the best one. The purpose of this study was to assess the value of central 2-10 perimetry in early detect...

متن کامل

Corneal Ectasis among Wrestlers: Report of Two Cases

Report keratoconus in two patients with a long history of wrestling without any risk factor for corneal ectasia and reviewing the possible pathogenesis. To confirm suspicion of keratoconus, corneal topography was performed using scanning slit topography system and Orbscan. In two wrestlers with the complaint of visual loss in their eyes and IOP raising, corneal topography was performed and de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000