Parallel computing techniques for computed tomography
نویسنده
چکیده
X-ray computed tomography is a widely adopted medical imaging method that uses projections to recover the internal image of a subject. Since the invention of X-ray computed tomography in the 1970s, several generations of CT scanners have been developed. As 3D-image reconstruction increases in popularity, the long processing time associated with these machines has to be significantly reduced before they can be practically employed in everyday applications. Parallel computing is a computer science computing technique that utilizes multiple computer resources to process a computational task simultaneously; each resource computes only a part of the whole task thereby greatly reducing computation time. In this thesis, we use parallel computing technology to speed up the reconstruction while preserving the image quality. Three representative reconstruction algorithms—namely, Katsevich, EM, and Feldkamp algorithms—are investigated in this work. With the Katsevich algorithm, a distributed-memory PC cluster is used to conduct the experiment. This parallel algorithm partitions and distributes the projection data to different computer nodes to perform the computation. Upon completion of each sub-task, the results are collected by the master computer to produce the final image. This parallel algorithm uses the same reconstruction formula as the sequential counterpart, which gives an identical image result. The parallelism of the iterative CT algorithm uses the same PC cluster as in the first one. However, because it is based on a local CT reconstruction algorithm, which is different from the sequential EM algorithm, the image results are different with the sequential counterpart. Moreover, a special strategy using inhomogeneous resolution was used to further speed up the computation. The results showed that the image quality was largely preserved while the computational time was greatly reduced. Unlike the two previous approaches, the third type of parallel implementation uses a shared-memory computer. Three major accelerating methods—SIMD (Single
منابع مشابه
Fast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملReview of Parallel Computing Techniques for Computed Tomography Image Reconstruction
After we briefly review representative analytic and iterative reconstruction algorithms for X-ray computed tomography (CT), we address the need for faster reconstruction by parallel computing techniques. For a decent, a cone-beam reconstruction usually takes hours on a regular PC, since most of algorithms take more than 60 iterations even longer. In order to speedup the performance, people intr...
متن کاملAn approach to fault detection and correction in design of systems using of Turbo codes
We present an approach to design of fault tolerant computing systems. In this paper, a technique is employed that enable the combination of several codes, in order to obtain flexibility in the design of error correcting codes. Code combining techniques are very effective, which one of these codes are turbo codes. The Algorithm-based fault tolerance techniques that to detect errors rely on the c...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016