Infarct Size Measured by Single Photon Emission Computed Tomographic Imaging With Tc-Sestamibi A Measure of the Efficacy of Therapy in Acute Myocardial Infarction

نویسنده

  • Raymond J. Gibbons
چکیده

Background—Use of mortality as an end point in randomized trials of reperfusion therapy requires increasingly large sample sizes to test advances compared with existing therapy, which is already highly effective. There has been a growing interest in infarct size measurements by Tc-sestamibi SPECT (single photon emission computed tomographic) imaging as a surrogate end point. Methods and Results—We reviewed the reports published in English regarding infarct size measurements by Tcsestamibi. Four separate lines of published evidence support the validity of SPECT imaging with Tc-sestamibi for determination of infarct size. This end point has been used in a total of 7 randomized trials—1 single center and 6 multicenter. The end point compares favorably with left ventricular function and infarct size measurements with the use of other radiopharmaceuticals. The most important limitation of this approach is the absence thus far of a randomized trial that has shown a corresponding decrease in mortality in association with a therapy that reduces infarct size. Conclusions—SPECT imaging with Tc-sestamibi is the best available measurement tool for infarct size. It has already served as an end point in early pilot studies to evaluate potential efficacy and in dose-ranging studies. It has the potential to serve as a surrogate end point to uncover advantages of new therapies that may be equivalent to existing therapies with respect to early mortality. (Circulation. 2000;101:101-108.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Infarct size measured by single photon emission computed tomographic imaging with (99m)Tc-sestamibi: A measure of the efficacy of therapy in acute myocardial infarction.

BACKGROUND Use of mortality as an end point in randomized trials of reperfusion therapy requires increasingly large sample sizes to test advances compared with existing therapy, which is already highly effective. There has been a growing interest in infarct size measurements by (99m)Tc-sestamibi SPECT (single photon emission computed tomographic) imaging as a surrogate end point. METHODS AND ...

متن کامل

The missing aortic prosthesis: an unusual case of pseudo-aortic regurgitation.

cardial infarction in patients presenting with ST-segment elevation: the Task Force on the management of ST-segment elevation acute myocardial infarction of the European Society of Cardiology (ESC). Eur Heart J 2012;33:2569–619. 5. Gibbons RJ, Miller TD, Christian TF. Infarct size measured by single photon emission computed tomographic imaging with (99 m)Tc-sestamibi: a measure of the efficacy ...

متن کامل

TIMI myocardial perfusion grade and ST segment resolution: association with infarct size as assessed by single photon emission computed tomography imaging.

BACKGROUND The TIMI myocardial perfusion grade (TMPG) and ST-segment resolution both reflect perfusion and are associated with mortality after thrombolysis for acute myocardial infarction. We hypothesized that these measures would also be associated with infarct size by single photon emission computed tomography (SPECT). Methods and Results- In the LIMIT AMI trial (Limitation of Myocardial Inju...

متن کامل

The quantification of infarct size.

We sought to summarize the published evidence regarding the measurement of infarct size by serum markers, technetium-99m sestamibi single-photon emission computed tomography (SPECT) myocardial perfusion imaging, and magnetic resonance imaging. The measurement of infarct size is an attractive surrogate end point for the early assessment of new therapies for acute myocardial infarction. For each ...

متن کامل

Assessment of infarcted myocardium with real time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single photon emission computed tomography.

BACKGROUND Little is known about the relation between the extent of microvascular damage and infarct size in patients after successful mechanical reperfusion of acute myocardial infarction. OBJECTIVE To compare the spatial extent of reduced myocardial signal between real time myocardial contrast echocardiography (MCE) and single photon emission computed tomography (SPECT) after successful mec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999