High - Resolution 3 - D Refractive Index Imaging
نویسندگان
چکیده
This thesis presents a theory of 3-D imaging in partially coherent light under a non-paraxial condition. The transmission cross-coefficient (TCC) has been used to characterize partially coherent imaging in a 2D and 3-D paraxial model. It is shown that the 3-D TCC under the non-paraxial condition is an overlap integral of three hemispheres or 3-D pupil functions. By an inspection of the overlap integral, a simple formula is derived that can be efficiently calculated by multiple applications of the 3-D fast Fourier transform (FFT) instead of a 6-D integral. The theory is applied to phase contrast and differential interference contrast (DIC), and it provides the most rigorous 3-D model that has ever been suggested. Contrast-agent-free microscopy is highly desirable to study the dynamics and physiological activity of various structures in living cells. Refractive index is an intrinsic contrast source, but at the same time it is an important biochemical parameter that is proportional to the concentration of molecules. By measuring the refractive index quantitatively, the alteration of cells under chemicals or drugs as well as their normal physiological activities can be monitored in most native conditions. This thesis presents 3-D optical diffraction tomography (ODT) to retrieve the 3-D refractive index map of a transparent biological sample and applies them to some interesting biological problems: the study of cell growth and monitoring the effect of drugs on multiple myeloma cells. In most practical applications of ODT, the angular coverage of an incident beam is limited due to finite system numerical aperture. The refractive index map reconstructed from the restricted data set suffers from the missing cone artifact: elongation of the reconstructed shape along the optical axis and underestimation of the value of the refractive index. This thesis presents that the missing-cone artifact can be effectively suppressed by applying positivity and piecewise-smoothness constraints in the iterative reconstruction framework. By filling the missing cone, a 3-D refractive index map can be reconstructed from the scattering into the entire 4-nt solid angle. . With the improved accuracy, we attempt to quantify the dry mass of chromosomes in single living cells in their mitotic phase. Thesis reader: Roger Kamm, Professor of Mechanical Engineering, and Biological Engineering, MIT Thesis reader: Colin J. R. Sheppard, Professor and Head of the Division of Bioengineering, NUS Thesis reader: Peter So, Professor of Mechanical Engineering, and Biological Engineering, MIT Thesis Supervisor: George Barbastathis Title: Professor of Mechanical Engineering
منابع مشابه
Synthesis and super-resolution imaging performance of a refractive-index-controllable microsphere superlens
Microspheres can function as optical superlenses for nanoscale super-resolution imaging. The imaging performance is mainly affected by the size and refractive index of the microsphere. Precise control of these parameters is a challenging task but of fundamental importance to the further development of the technique. In this study, we demonstrate for the first time a nanoparticle-hybrid suspensi...
متن کاملLabel-free high-resolution 3-D imaging of gold nanoparticles inside live cells using optical diffraction tomography.
Delivery of gold nanoparticles (GNPs) into live cells has high potentials, ranging from molecular-specific imaging, photodiagnostics, to photothermal therapy. However, studying the long-term dynamics of cells with GNPs using conventional fluorescence techniques suffers from phototoxicity and photobleaching. Here, we present a method for 3-D imaging of GNPs inside live cells exploiting refractiv...
متن کاملHigh refractive index immersion liquid for superresolution 3D imaging using sapphire-based aplanatic numerical aperture increasing lens optics.
Optically transparent immersion liquids with refractive index (n∼1.77) to match the sapphire-based aplanatic numerical aperture increasing lens (aNAIL) are necessary for achieving deep 3D imaging with high spatial resolution. We report that antimony tribromide (SbBr3) salt dissolved in liquid diiodomethane (CH2I2) provides a new high refractive index immersion l...
متن کاملImproving Axial Resolution in Confocal Microscopy with New High Refractive Index Mounting Media
Resolution, high signal intensity and elevated signal to noise ratio (SNR) are key issues for biologists who aim at studying the localisation of biological structures at the cellular and subcellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microsc...
متن کاملHigh-resolution three-dimensional imaging of red blood cells parasitized by Plasmodium falciparum and in situ hemozoin crystals using optical diffraction tomography.
We present high-resolution optical tomographic images of human red blood cells (RBC) parasitized by malaria-inducing Plasmodium falciparum (Pf)-RBCs. Three-dimensional (3-D) refractive index (RI) tomograms are reconstructed by recourse to a diffraction algorithm from multiple two-dimensional holograms with various angles of illumination. These 3-D RI tomograms of Pf-RBCs show cellular and subce...
متن کاملRefractive Index Sensing with D-Shaped Plastic Optical Fibers for Chemical and Biochemical Applications
We report the optimization of the length of a D-shaped plastic optical fiber (POF) sensor for refractive index (RI) sensing from a numerical and experimental point of view. The sensing principle is based on total internal reflection (TIR). POFs with 1 mm in diameter were embedded in grooves, realized in planar supports with different lengths, and polished to remove the cladding and part of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011