A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia
نویسندگان
چکیده
BACKGROUND The C-MAC® (Karl Storz, Tuttlingen, Germany) has recently been introduced as a new device for videolaryngoscopy guided intubation. The purpose of the present study was to compare for the first time the C-MAC with conventional direct laryngoscopy in 150 patients during routine induction of anaesthesia. METHODS After approval of the institutional review board and written informed consent, 150 patients (ASA I-III) with general anaesthesia were enrolled. Computer-based open crossover randomisation was used to determine the sequence of the three laryngoscopies: Conventional direct laryngoscopy (HEINE Macintosh classic, Herrsching, Germany; blade sizes 3 or 4; DL group), C-MAC size 3 (C-MAC3 group) and C-MAC size 4 (C-MAC4 group) videolaryngoscopy, respectively. After 50 patients, laryngoscopy technique in the C-MAC4 group was changed to the straight blade technique described by Miller (C-MAC4/SBT). RESULTS Including all 150 patients (70 male, aged (median [range]) 53 [20-82] years, 80 [48-179] kg), there was no difference of glottic view between DL, C-MAC3, C-MAC4, and C-MAC4/SBT groups; however, worst glottic view (C/L 4) was only seen with DL, but not with C-MAC videolaryngoscopy. In the subgroup of patients that had suboptimal glottic view with DL (C/L≥2a; n = 24), glottic view was improved in the C-MAC4/SBT group; C/L class improved by three classes in 5 patients, by two classes in 2 patients, by one class in 8 patients, remained unchanged in 8 patients, or decreased by two classes in 1 patient. The median (range) time taken for tracheal intubation in the DL, C-MAC3, C-MAC4 and C-MAC4/SBT groups was 8 sec (2-91 sec; n = 44), 10 sec (2-60 sec; n = 37), 8 sec (5-80 sec; n = 18) and 12 sec (2-70 sec; n = 51), respectively. CONCLUSIONS Combining the benefits of conventional direct laryngoscopy and videolaryngoscopy in one device, the C-MAC may serve as a standard intubation device for both routine airway management and educational purposes. However, in patients with suboptimal glottic view (C/L≥2a), the C-MAC size 4 with straight blade technique may reduce the number of C/L 3 or C/L 4 views, and therefore facilitate intubation. Further studies on patients with difficult airway should be performed to confirm these findings.
منابع مشابه
Author's response to reviews Title: A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia Authors:
The term C-MAC Miller is confusing. I had read this over several times thinking that Storz had in fact produced a C-Miller blade. Perhaps the authors would consider abbreviating this as C-MAC/MT (for Miller technique) so that the Miller blade design is not so strongly suggested. We greatly appreciate this reviewers’ comment, since we were not aware of the current description being a basis for m...
متن کاملC-MAC videolaryngoscope compared with direct laryngoscopy for rapid sequence intubation in an emergency department: A randomised clinical trial.
BACKGROUND Airway management in the emergency room can be challenging when patients suffer from life-threatening conditions. Mental stress, ignorance of the patient's medical history, potential cervical injury or immobilisation and the presence of vomit and/or blood may also contribute to a difficult airway. Videolaryngoscopes have been introduced into clinical practice to visualise the airway ...
متن کاملClinical experience with the C-Mac videolaryngoscope in morbidly obese patients.
BACKGROUND The use of videolaryngoscopes is recommended as a part of routine practice in anaesthesia for morbidly obese patients. The aim of this study was to evaluate C-Mac in a group of morbidly obese patients to see if it improves intubation conditions. METHODS 86 morbidly obese (BMI > 40 kg m⁻²) patients scheduled for bariatric surgery were included in the study. In every studied case, C-...
متن کاملCurrent evidence for the use of C-MAC videolaryngoscope in adult airway management: a review of the literature
The C-MAC videolaryngoscope is the first Macintosh-typed videolaryngoscope. Since the advent of its original version video Macintosh system in 1999, this device has been modified several times. A unique feature of C-MAC device is its ability to provide the 2 options of direct and video laryngoscopy with the same device. The available evidence shows that in patients with normal airways, C-MAC vi...
متن کاملTracheal intubation performed with GlideScope® video laryngoscope and direct laryngoscopy in neonates and infants.
1. Aziz MF, Dillman D, Fu R, Brambrink AM: Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway. ANESTHESIOLOGY 2012; 116:629 –36 2. Aziz MF, Healy D, Kheterpal S, Fu RF, Dillman D, Brambrink AM: Routine clinical practice effectiveness of the Glidescope in difficult airway management: An analysis of 2,004 Glidescop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2011