A novel servo-control system that imposes desired aortic input impedance on in situ rat heart.

نویسندگان

  • H Miyashita
  • M Sugimachi
  • T Sato
  • T Kawada
  • T Shishido
  • T Nakahara
  • R Yoshimura
  • H Takaki
  • H Miyano
  • K Sunagawa
چکیده

To clarify the pathophysiological role of dynamic arterial properties in cardiovascular diseases, we attempted to develop a new control system that imposes desired aortic impedance on in situ rat left ventricle. In 38 anesthetized open-chest rats, ascending aortic pressure and flow waveforms were continuously sampled (1,000 Hz). Desired flow waveforms were calculated from measured aortic pressure waveforms and target impedance. To minimize the difference between measured and desired aortic flow waveforms, the computer generated commands to the servo-pump, connected to a side branch of the aorta. By iterating the process, we could successfully control aortic impedance in such a way as to manipulate compliance and characteristic impedance between 60 and 160% of their respective native values. The error between desired and measured aortic flow waveforms was 70 +/- 34 microl/s (root mean square; 4.4 +/- 1.4% of peak flow), indicating reasonable accuracy in controlling aortic impedance. This system enables us to examine the importance of dynamic arterial properties independently of other hemodynamic and neurohumoral factors in physiological and clinical settings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling, Control and Simulation of Cascade Control Servo System for one Axis Gimbal Mechanism

The gimbal stabilization mechanism is used to provide the stability to an object mounted on the gimbal by isolating it from the base angular motion and vibration. The purpose of this paper is to present a model of control servo system for one axis gimbal mechanism using a cascade PID controller. The gimbal torque relationships are derived by taking into consideration the base angular motion. Th...

متن کامل

Adaptive Speed Control of Three-Phase Induction Servo-drives Based on Feedback Linearization Theory

In this paper, based on feedback linearization control method and using a special PI (propotational integrator) regulator (IP) in combination with a feed-forward controller, a three-phase induction servo-drive is speed controlled. First, an observer is employed to estimate the rotor d and q axis flux components. Then, two input-output state variables are introduced to control the dynamics of to...

متن کامل

Aortic input impedance in heart failure.

The input impedance of the systemic circulation was calculated from recordings of pulsatile pressure and flow in the ascending aorta of 20 patients. Ten patients had clinical and hemodynamic evidence of heart failure. The other 10 subjects had no clinical evidence of heart failure and were used as a control group. In the heart failure patients, both input resistance and characteristic impedance...

متن کامل

Adaptive Speed Control of Three-Phase Induction Servo-drives Based on Feedback Linearization Theory

In this paper, based on feedback linearization control method and using a special PI (propotational integrator) regulator (IP) in combination with a feed-forward controller, a three-phase induction servo-drive is speed controlled. First, an observer is employed to estimate the rotor d and q axis flux components. Then, two input-output state variables are introduced to control the dynamics of to...

متن کامل

Design Servo System Type and Positioning of Pole Observer Full Rank a Piezoelectric Servo Valve without Integrator

In this paper, the method of modern control approach for the design of controller and observer is used. Other functions such as neural controllers - or fuzzy sliding mode control can be found in this work and the results are compared. First, a dynamic model of the servo valve is intended for the governing equations in state-space form expression are obtained. Due to the system integrator is exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 278 3  شماره 

صفحات  -

تاریخ انتشار 2000