BACKGROUND AND PURPOSE Hyperintense signals on diffusion-weighted MR images (DWIs) are believed to correspond accurately with cerebral ischemic events. Intraoperative transcranial Doppler sonography (TCD) can reveal hemodynamic and embolic events during carotid endarterectomy (CEA). Our purpose was to determine whether the occurrence of hyperintense signals on postoperative DWIs corresponds to intraoperative embolic or hemodynamic events. METHODS Seventy-seven CEAs were monitored intraoperatively with TCD to record blood flow velocity changes after cross clamping to ascertain the presence of adequate collateral flow and to record microembolic signals. DWI was used to classify the hemisphere ipsilateral to the CEA by type: 0, no lesions (n = 51); I, cortical lesions only (n = 2); II, subcortical white matter lesions only (n = 6); III, mixed type with cortical and subcortical lesions (n = 11); IV, large territorial infarcts (n = 6); and V, other types of lesions (n = 1). RESULTS Neither the five clinical events (one transient ischemic attack, two minor strokes, and two major strokes) nor any DWI type (I-V) showed a relationship to blood velocity decreases after cross clamping or, in patients who were selectively shunted, to total ischemic time necessary for shunt insertion and removal. Total microembolic signal count was significantly higher in the five CEAs with clinical events than in those without. It was also higher on the DWIs showing a hyperintense lesion as compared with DWIs showing no lesion. CONCLUSION Apart from lesions corresponding to clinical deficits, CEA is associated with a substantial number of small areas of brain tissue at risk for irreversible ischemia. The main cause of intraoperative stroke seems to be embolism, suggesting that microembolic signals in CEA are highly relevant events for brain tissue.
منابع مشابه
Detection of clinically silent infarcts after carotid endarterectomy by use of diffusion-weighted imaging.
BACKGROUND AND PURPOSE Intraprocedural transcranial Doppler sonography has identified multiple microembolic events during and immediately after carotid endarterectomy (CEA) or angioplasty, yet the rate of clinically evident stroke is small. To determine the significance of the transcranial Doppler sonography findings, we examined patients by use of diffusion-weighted imaging and fluid-attenuate...
متن کاملMicroembolic signals detected by transcranial Doppler sonography during carotid endarterectomy and correlation with serial diffusion-weighted imaging.
BACKGROUND AND PURPOSE Embolic events are a major cause for procedure-related strokes after carotid endarterectomy (CEA). Transcranial Doppler sonography can reveal embolic events as microembolic signals (MES) during CEA. MES during declamping and shunting are frequently detected. MES during shunting are rare and known to be correlated with the neurological outcome of the patient. In the presen...
متن کاملPreoperative 3D FSE T1-Weighted MR Plaque Imaging for Severely Stenotic Cervical ICA: Accuracy of Predicting Emboli during Carotid Endarterectomy
The aim of the present study was to determine whether preoperative three-dimensional (3D) fast spin-echo (FSE) T1-weighted magnetic resonance (MR) plaque imaging for severely stenotic cervical carotid arteries could accurately predict the development of artery-to-artery emboli during exposure of the carotid arteries in carotid endarterectomy (CEA). Seventy-five patients underwent preoperative M...
متن کاملPlaque hemorrhage is a marker of thromboembolic activity in patients with symptomatic carotid disease.
PURPOSE To assess whether carotid plaque hemorrhage depicted with magnetic resonance (MR) imaging was associated with thromboembolic activity as assessed with transcranial Doppler imaging. MATERIALS AND METHODS The local research ethics committee approved the study, and all patients gave informed written consent. Between April 2005 and December 2006, patients with high-grade symptomatic carot...
متن کاملAssessment of blood flow velocity and diameter of the middle cerebral artery during the acetazolamide provocation test by use of transcranial Doppler sonography and MR imaging.
BACKGROUND AND PURPOSE Our purpose was to show changes in the diameter of the M1 segment of the middle cerebral artery (MCA) by using high-resolution MR imaging in patients with chronic internal carotid artery occlusion after IV administered acetazolamide challenge. Changes in blood flow velocity of the basal cerebral arteries are thought to correlate with changes of cerebral blood flow. Change...