Microstructure of 5 keV gold-implanted polydimethylsiloxane
نویسندگان
چکیده
منابع مشابه
Comparison of two Metal Ion Implantation Techniques for Fabrication of Gold and Titanium Based Compliant Electrodes on Polydimethylsiloxane
This study contrasts the implantation of 25 μm thick Polydimethylsiloxane (PDMS) membranes with titanium and gold ions at 10 keV and 35 keV for doses from 1x10 15 at/cm 2 to 2.5x10 16 at/cm 2 implanted with two different techniques: Filtered Cathodic Vacuum Arc (FCVA) and Low Energy Broad Ion Beam (LEI). The influence of the ion energy, ion type, and implantation tool on the Young’s modulus (E)...
متن کاملOptical and Electrical Properties of Nitrogen Ion Implanted Fluorine Doped Tin Oxide Films
Tin oxide films were implanted with N at various energies between 5 to 40 keV for different ion doses between 10 to 10 cm. The microstructure, optical and electrical properties of the films were investigated. From Transmission Electron Microscopy the implanted films were shown to be amorphous. The implanted thickness for the 10 keV and 40 keV were found to be 30 nm and 110 nm, respectively. The...
متن کاملFerromagnetism and microstructure in Cr implanted p-type (100) silicon
The magnetic properties and microstructure of p-type Si (100) implanted with 1.0 × 1015 cm−2 of Cr ions at 200 keV have been investigated by a superconducting quantum interference device (SQUID) magnetometer, scanning electron microscope (SEM) and transmission electron microscopy (TEM). The magnetic hysteresis loops and saturation magnetization of 0.67–0.75 emu/g in a wide temperature range are...
متن کاملThe Effects Of Interfacial Roughness On The Argon Ion Implanted Tantalum Films
In the present study, effect of interfacial roughness on the ion implanted Tantalum based surfaces has been investigated. The argon ions with energy of 30 keV and in doses of 1×1017 , 3×1017 , 5×1017 , 7×1017 , and 10×1017 (ion/cm2) have been used at ambient temperature. The Atomic Force Microscopy (AFM), analysis have been used to study and characterize the surfaces morphology. The effect of ...
متن کاملElectrical conductivity and Young’s modulus of flexible nanocomposites made by metal-ion implantation of polydimethylsiloxane: The relationship between nanostructure and macroscopic properties
The mechanical and electrical properties of nanocomposites created by gold and titanium implantation into polydimethysiloxane (PDMS) are reported for doses from 10 to 5 10 at. cm , and for ion energies of 2.5, 5 and 10 keV. Transmission electron microscopy (TEM) cross-section micrographs allowed detailed microstructural analysis of the implanted layers. Gold ions penetrate up to 30 nm and form ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008