Immersogeometric cardiovascular fluid-structure interaction analysis with divergence-conforming B-splines.

نویسندگان

  • David Kamensky
  • Ming-Chen Hsu
  • Yue Yu
  • John A Evans
  • Michael S Sacks
  • Thomas J R Hughes
چکیده

This paper uses a divergence-conforming B-spline fluid discretization to address the long-standing issue of poor mass conservation in immersed methods for computational fluid-structure interaction (FSI) that represent the influence of the structure as a forcing term in the fluid subproblem. We focus, in particular, on the immersogeometric method developed in our earlier work, analyze its convergence for linear model problems, then apply it to FSI analysis of heart valves, using divergence-conforming B-splines to discretize the fluid subproblem. Poor mass conservation can manifest as effective leakage of fluid through thin solid barriers. This leakage disrupts the qualitative behavior of FSI systems such as heart valves, which exist specifically to block flow. Divergence-conforming discretizations can enforce mass conservation exactly, avoiding this problem. To demonstrate the practical utility of immersogeometric FSI analysis with divergence-conforming B-splines, we use the methods described in this paper to construct and evaluate a computational model of an in vitro experiment that pumps water through an artificial valve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isogeometric divergence-conforming B-splines for the unsteady Navier-Stokes equations

Divergence-conforming B-splines are developed for application to the incompressible Navier-Stokes equations on geometrically mapped domains. These enable smooth, pointwise divergence-free solutions and thus satisfy mass conservation in the strongest possible sense. Semi-discrete methods based on divergence-conforming B-splines are shown to conserve linear and angular momentum and satisfy balanc...

متن کامل

Rapid B-rep model preprocessing for immersogeometric analysis using analytic surfaces

Computational fluid dynamics (CFD) simulations of flow over complex objects have been performed traditionally using fluid-domain meshes that conform to the shape of the object. However, creating shape conforming meshes for complicated geometries like automobiles require extensive geometry preprocessing. This process is usually tedious and requires modifying the geometry, including specialized o...

متن کامل

A framework for designing patient-specific bioprosthetic heart valves using immersogeometric fluid-structure interaction analysis.

Numerous studies have suggested that medical image derived computational mechanics models could be developed to reduce mortality and morbidity due to cardiovascular diseases by allowing for patient-specific surgical planning and customized medical device design. In this work, we present a novel framework for designing prosthetic heart valves using a parametric design platform and immersogeometr...

متن کامل

Stability and conservation properties of collocated constraints in immersogeometric fluid–thin structure interaction analysis

The purpose of this study is to enhance the stability properties of our recentlydeveloped numerical method [D. Kamensky, M.-C. Hsu, D. Schillinger, J.A. Evans, A. Aggarwal, Y. Bazilevs, M.S. Sacks, T.J.R. Hughes, “An immersogeometric variational framework for fluid–structure interaction: Application to bioprosthetic heart valves”, Comput. Methods Appl. Mech. Engrg., 284 (2015) 1005–1053] for im...

متن کامل

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods in applied mechanics and engineering

دوره 314  شماره 

صفحات  -

تاریخ انتشار 2017