Energy and Position Reconstruction in Pixelated CdZnTe Detectors
نویسندگان
چکیده
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
منابع مشابه
Charge sharing in common-grid pixelated CdZnTe detectors
The charge sharing effect in pixelated CdZnTe (CZT) detectors with a common anode steering grid has been studied. The impact on energy resolution of weighting potential cross-talk and ballistic deficit due to cathode signal shaping has been investigated. A detailed system modeling package considering charge induction, electronic noise, pulse shaping, and ASIC triggering procedures has been deve...
متن کاملImpact of drift time variation on the Compton image from large-volume CdZnTe crystals
In pixelated CdZnTe detectors, multiple interaction gamma-ray events are critical because they permit Compton imaging. However, in large-volume CdZnTe crystals, the depth of multiple interaction events is often poorly reconstructed due to significant nonuniformity of electron drift velocity while the depth of single interaction events can be accurately reconstructed using signal ratios. The non...
متن کاملDirect measurement of product of the electron mobility and mean free drift time of CdZnTe semiconductors using position sensitive single polarity charge sensing detectors
Related Articles A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter Rev. Sci. Instrum. 83, 013304 (2012) A transport-based model of material trends in nonproportionality of scintillators J. Appl. Phys. 109, 123716 (2011) A digital method for separation and reconstruction of pile-up events in germanium detectors Rev. Sci. Instrum. 81, 103...
متن کامل3D position sensitive CdZnTe gamma-ray spectrometers – improved performance with new ASICs
A 3-dimensional position sensitive CdZnTe gamma-ray spectrometer based on VAS3.1/TAT3 ASICs was developed and tested. The 3-D CZT spectrometer employs a 1.5 × 1.5 × 1 cm CdZnTe crystal with 11 by 11 pixelated anodes wire-bonded to the readout electronics. The signals from the anode pixels and the cathode were both read out through the ASICs. The pixel position provides the lateral 2-D coordinat...
متن کاملProgress in the Development of CdZnTe Unipolar Detectors for Different Anode Geometries and Data Corrections
CdZnTe detectors have been under development for the past two decades, providing good stopping power for gamma rays, lightweight camera heads and improved energy resolution. However, the performance of this type of detector is limited primarily by incomplete charge collection problems resulting from charge carriers trapping. This paper is a review of the progress in the development of CdZnTe un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012