Robust fault detection system for insulin pump therapy using continuous glucose monitoring.

نویسندگان

  • Pau Herrero
  • Remei Calm
  • Josep Vehí
  • Joaquim Armengol
  • Pantelis Georgiou
  • Nick Oliver
  • Christofer Tomazou
چکیده

BACKGROUND The popularity of continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, as a way to deliver insulin more physiologically and achieve better glycemic control in diabetes patients has increased. Despite the substantiated therapeutic advantages of using CSII, its use has also been associated with an increased risk of technical malfunctioning of the device, which leads to an increased risk of acute metabolic complications, such as diabetic ketoacidosis. Current insulin pumps already incorporate systems to detect some types of faults, such as obstructions in the infusion set, but are not able to detect other types of fault such as the disconnection or leakage of the infusion set. METHODS In this article, we propose utilizing a validated robust model-based fault detection technique, based on interval analysis, for detecting disconnections of the insulin infusion set. For this purpose, a previously validated metabolic model of glucose regulation in type 1 diabetes mellitus (T1DM) and a continuous glucose monitoring device were used. As a first step to assess the performance of the presented fault detection system, a Food and Drug Administration-accepted T1DM simulator was employed. RESULTS Of the 100 in silico tests (10 scenarios on 10 subjects), only two false negatives and one false positive occurred. All faults were detected before plasma glucose concentration reached 300 mg/dl, with a mean plasma glucose detection value of 163 mg/dl and a mean detection time of 200 min. CONCLUSIONS Interval model-based fault detection has been proven (in silico) to be an effective tool for detecting disconnection faults in sensor-augmented CSII systems. Proper quantification of the uncertainty associated with the employed model has been observed to be crucial for the good performance of the proposed approach.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fractional Order Glucose Insulin System Using Fractional Back-Stepping Sliding Mode Control

In this paper, based on a fractional order Bergman minimal model, a robust strategy for regulationof blood glucose in type 1 diabetic patients is presented. Glucose/insulin concentration in the patientbody is controlled through the injection under the patients skin by the pump. Many various con-trollers for this system have been proposed in the literature. However, most of the...

متن کامل

Mitigating Severe Hypoglycemia by Initiating Inpatient Continuous Glucose Monitoring for Type 1 Diabetes Mellitus.

 Continuous glucose monitoring for type 1 diabetes mellitus will go forward for refinement as a systematic review. The scope of this topic, including populations, interventions, comparators, and outcomes, will be further developed in the refinement phase.  When key questions have been drafted, they will be posted on the AHRQ Web site and open for public comment. To sign up for notification wh...

متن کامل

Combined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience.

OBJECTIVES This study assessed the safety and clinical effectiveness of the training protocol for initiating insulin pump therapy with real-time continuous glucose monitoring (MiniMed Paradigm REAL-Time System) in a stepwise approach on pump naive subjects with type 1 diabetes compared to a control group who remained on multiple daily injection (MDI) therapy. METHODS This was a 15-week treat-...

متن کامل

Incremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 Diabetes

OBJECTIVE To compare the improvements in glycemic control associated with transitioning to insulin pump therapy in patients using continuous glucose monitoring versus standard blood glucose self-monitoring. RESEARCH DESIGN AND METHODS The RealTrend study was a 6-month, randomized, parallel-group, two-arm, open-label study of 132 adults and children with uncontrolled type 1 diabetes (A1C >or=8...

متن کامل

Insulin pump therapy: guidelines for successful outcomes.

PURPOSE Current forms of insulin delivery used in the treatment of diabetes mellitus (diabetes) include syringes, pens, and insulin pumps. Technical advantages of insulin pump therapy, or continuous subcutaneous insulin delivery (CSII), include precise and flexible insulin dosing. In the context of intensive diabetes management, insulin pumps can facilitate improved long-term glycemic control a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 6 5  شماره 

صفحات  -

تاریخ انتشار 2012