Left ventricular sensing and pacing for sensing difficulties in internal cardioverter defibrillator therapy for arrhythmogenic right ventricular cardiomyopathy.
نویسندگان
چکیده
Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a disease where therapy with an internal cardioverter defibrillator (ICD) is frequently indicated, but the use of these devices is often challenged because of sensing dysfunction with low right ventricular sensing amplitude. We present the case of an ARVC patient in whom ICD sensing difficulties were overcome by the implantation of a coronary sinus lead for pacing and sensing.
منابع مشابه
A case of premature ventricular contractions, ventricular tachycardia, and arrhythmic storm induced by right ventricular pacing during cardiac resynchronization therapy: Electrophysiological mechanism and catheter ablation.
A 77-year-old man with ischemic cardiomyopathy and a cardiac resynchronization therapy-defibrillator (CRT-D) device came to our attention due to incessant ventricular tachycardia and multiple implantable cardioverter defibrillator (ICD) shocks. An electrocardiogram showed non-sustained monomorphic ventricular tachycardias (NSVTs) constantly occurring after each biventricular stimulation. During...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملTwiddler's syndrome in a patient with a single-chamber implantable cardioverter defibrillator.
A 67-year-old, obese, Caucasian female with a history of ischaemic dilated cardiomyopathy and ventricular fibrillation, underwent a single-chamber implantable cardioverter defibrillator (ICD) with a screw, in ventricular lead implantation. Appropriate sensing, pacing, and defibrillation thresholds were obtained at implantation. A chest X-ray after implantation demonstrated a proper lead positio...
متن کاملThrombus formation on a defibrillator lead with conductor externalization
A 51 year old man with arrhythmogenic right ventricular cardiomyopathy reported non-specific symptoms of muscle aches and shivering at outpatient review. A dual chamber implantable cardioverter defibrillator (ICD) had been inserted seven years previously. Fluoroscopic lead screening had previously demonstrated conductor externalisation (Figure and Video) of a single coil Riata ICD lead (model n...
متن کاملPredictors of Appropriate ICD Therapy in Patients with Arrhythmogenic Right Ventricular Cardiomyopathy: Long Term Experience of a Tertiary Care Center
INTRODUCTION Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetically transmitted disease prone to ventricular arrhythmias. We therefore investigated the clinical, echocardiographical and electrophysiological predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in patients with ARVC. METHODS A retrospective analysis was performed in 26 patients (m...