Biological and Technical Variables Affecting Immunoassay Recovery of Cytokines from Human Serum and Simulated Vaginal Fluid: A Multicenter Study

نویسندگان

  • Raina N. Fichorova
  • Nicola Richardson-Harman
  • Massimo Alfano
  • Laurent Belec
  • Cedric Carbonneil
  • Silvia Chen
  • Lisa Cosentino
  • Kelly Curtis
  • Charlene S. Dezzutti
  • Betty Donoval
  • Gustavo F. Doncel
  • Melissa Donaghay
  • Jean-Charles Grivel
  • Esmeralda Guzman
  • Madeleine Hayes
  • Betsy Herold
  • Sharon Hillier
  • Carol Lackman-Smith
  • Alan Landay
  • Leonid Margolis
  • Kenneth H. Mayer
  • Jenna-Malia Pasicznyk
  • Melanie Pallansch-Cokonis
  • Guido Poli
  • Patricia Reichelderfer
  • Paula Roberts
  • Irma Rodriguez
  • Hela Saidi
  • Rosaria Rita Sassi
  • Robin Shattock
  • James E. Cummins, Jr.
چکیده

The increase of proinflammatory cytokines in vaginal secretions may serve as a surrogate marker of unwanted inflammatory reaction to microbicide products topically applied for the prevention of sexually transmitted diseases, including HIV-1. Interleukin (IL)-1beta and IL-6 have been proposed as indicators of inflammation and increased risk of HIV-1 transmission; however, the lack of information regarding detection platforms optimal for vaginal fluids and interlaboratory variation limit their use for microbicide evaluation and other clinical applications. This study examines fluid matrix variants relevant to vaginal sampling techniques and proposes a model for interlaboratory comparisons across current cytokine detection technologies. IL-1beta and IL-6 standards were measured by 12 laboratories in four countries, using 14 immunoassays and four detection platforms based on absorbance, chemiluminescence, electrochemiluminescence, and fluorescence. International reference preparations of cytokines with defined biological activity were spiked into (1) a defined medium simulating the composition of human vaginal fluid at pH 4.5 and 7.2, (2) physiologic salt solutions (phosphate-buffered saline and saline) commonly used for vaginal lavage sampling in clinical studies of cytokines, and (3) human blood serum. Assays were assessed for reproducibility, linearity, accuracy, and significantly detectable fold difference in cytokine level. Factors with significant impact on cytokine recovery were determined by Kruskal-Wallis analysis of variance with Dunn's multiple comparison test and multiple regression models. All assays showed acceptable intra-assay reproducibility; however, most were associated with significant interlaboratory variation. The smallest reliably detectable cytokine differences ( P < 0.05) derived from pooled interlaboratory data varied from 1.5- to 26-fold depending on assay, cytokine, and matrix type. IL-6 but not IL-1beta determinations were lower in both saline and phosphate-buffered saline as compared to vaginal fluid matrix, with no significant effect of pH. The (electro)chemiluminescence-based assays were most discriminative and consistently detected <2-fold differences within each matrix type. The Luminex-based assays were less discriminative with lower reproducibility between laboratories. These results suggest the need for uniform vaginal sampling techniques and a better understanding of immunoassay platform differences and cross-validation before the biological significance of cytokine variations can be validated in clinical trials. This investigation provides the first standardized analytic approach for assessing differences in mucosal cytokine levels and may improve strategies for monitoring immune responses at the vaginal mucosal interface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES

Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...

متن کامل

Technological and Probiotic Traits of the Lactobacilli Isolated From Vaginal Tract of the Healthy Women for Probiotic Use

Background: For biotechnological application, selected lactic acid bacteria strains belonging to the genera Lactobacillus (Lb) are proposed as an alternative to the antibiotics for the prevention and treatment of urogenital tract infections. Objectives: Isolating and selecting vaginal lactobacilli strains for probiotic use based on their technological and probiotic aptitudes. Materials and Meth...

متن کامل

Quantification of Human Chorionic Gonadotropin by Bovine Serum Albumin Nanoparticles

Background and Aims: Some nanoparticles can be used in immunoassays to increase sensitivity. This study aimed to evaluate a novel nano-immunoassay based on bovine serum albumin nanoparticles (BSA NPs). Materials and methods: At first, the nanostructure was synthesized, and then applied as a tag in the nano-immunoassay. Then the concentration of &beta;-subunit of human chorionic gonadotropin ...

متن کامل

بررسی تأثیر دود ماشین در میزان سیتوکین‌های TNF-α، IFN-γو IL-2 در سرم رت‌ها

Abstract Background: Any substance in the atmosphere that changes its physical, chemical and biological properties causes air pollution. These contaminants can enter the human body through nose, skin, mouth and digestive system and threaten human health. Vehicles produce contaminants like lead, particulate matter, sulfur dioxide, nitrogen oxides, hydrocarbons and carbon monoxide. The purpose...

متن کامل

The Correlation between Serum and Peritoneal Fluid CA125 Level in Women with Pelvic Endometriosis

Background Despite a high prevalence of endometriosis, there still exist many challenges in diagnosing the disease. This study aims to evaluate non-invasive and practical diagnostic methods by measuring serum and peritoneal fluid CA 125 levels in patients with endometriosis. A secondary aim is to determine the correlation between these markers with the stage of disease as well as the relationsh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2008