Dynamic CT myelography: a technique for localizing high-flow spinal cerebrospinal fluid leaks.
نویسندگان
چکیده
In some patients with spontaneous spinal CSF leaks, leaks are numerous or tears are so large that extrathecal myelographic contrast material is seen at multiple levels during CT, making identification of their source impossible. This study introduces a dynamic CT myelographic technique that provides high temporal and spatial resolution. In this technical note, we describe the utility of this technique in four patients with challenging high-flow spinal CSF leaks.
منابع مشابه
Predicting High-Flow Spinal CSF Leaks in Spontaneous Intracranial Hypotension Using a Spinal MRI-Based Algorithm: Have Repeat CT Myelograms Been Reduced?
BACKGROUND AND PURPOSE We adopted an imaging algorithm in 2011 in which extradural fluid on spinal MR imaging directs dynamic CT myelography. We assessed algorithm compliance and its effectiveness in reducing repeat or unnecessary dynamic CT myelograms. MATERIALS AND METHODS CT myelograms for CSF leaks from January 2011 to September 2014 were reviewed. Patients with iatrogenic leaks, traumati...
متن کاملLocalization of cerebrospinal fluid leak in a case of spontaneous intracranial hypotension using dynamic computed tomography myelography.
388 August 2014 E blood patch is the mainstay of treatment for persistent symptoms secondary to spontaneous intracranial hypotension.1 Determining the level of cerebrospinal fluid leak is thought to be an important consideration for optimal siting of the epidural blood patch injection.2 However, it is often difficult to determine the level of cerebrospinal fluid leak in spontaneous intracranial...
متن کاملFloating dural sac sign is a sensitive magnetic resonance imaging finding of spinal cerebrospinal fluid leakage.
We would like to propose floating dural sac sign, which is observed as a hyperintense band or rim around the spinal dural sac on axial T2-weighted images, as a sensitive sign to identify cerebrospinal fluid (CSF) leakage. One hundred patients with orthostatic headache were prospectively registered in 11 hospitals. These patients were examined by brain magnetic resonance (MR) imaging (n = 89), r...
متن کاملDynamic computed tomography myelography for the investigation of cervical degenerative disease.
Dynamic computed tomography (CT) myelography was conducted in 15 patients with cervical degenerative disease to assess the lesions responsible for their symptoms. CT myelography was performed using a multi-detector row helical CT system in dynamic positions (flexion or extension or both) in addition to the neutral position. Fine sagittal reconstructed images could be obtained in addition to axi...
متن کاملApplication of time-spatial labeling inversion pulse magnetic resonance imaging in the diagnosis of spontaneous intracranial hypotension due to high-flow cerebrospinal fluid leakage at C1-2
BACKGROUND Spontaneous intracranial hypotension (SIH) due to cerebrospinal fluid (CSF) leakage at C1-2 poses diagnostic and therapeutic challenges to spine surgeons. Although computed tomography (CT) myelography has been the diagnostic imaging modality of choice for identifying the CSF leakage point, extradural CSF collection at C1-2 on conventional CT myelography or magnetic resonance imaging ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2003