Quadratic form: a robust metric for quantitative comparison of flow cytometric histograms.
نویسندگان
چکیده
Comparison of fluorescence distributions is a fundamental part of the analysis of flow cytometric data. This approach is applied to detect differences between control and test sample and thus analyze a biological response. Comparison of standard test samples over time provides an estimate of instrument stability for quality control. However, application of statistical methods of distribution comparison in flow cytometry is difficult owing to instrument noise and the complex shape of intensity distributions. We applied quadratic form (QF) as a mathematical metric for comparison of flow cytometry histograms. QF operates on histograms as vectors and calculates the total distance in an interbin manner using a matrix of distances between single histogram bins. Euclidean interbin distance and histograms normalized to unity were used. Critical values corresponding to 95% significance level were calculated using Monte-Carlo simulation and single-maximum Gaussian distributions populated with several numbers of events. The QF statistic was then validated for non-Gaussian single-maximum distributions and multiple-maxima distributions. We determined that the critical values for Gaussian distributions depended on standard deviations and number of events in the compared histograms. A simple empirical function was constructed to characterize this dependence. Furthermore, it was verified that critical values (corresponding to 95% significance) for non-Gaussian histograms were similar to values for the Gaussian histograms characterized by the same standard deviation. We applied the QF statistic to estimate the differences between histograms of DNA content (ploidy) in cells of old and young leaf tissue of Brassica campestris. Furthermore, we quantified differences in fluorescence intensity in immunostaining of human lymphocytes. Quadratic form (QF) provides a true (mathematical) metric for estimation of distance between flow cytometry histograms of arbitrary shape. QF can be applied as a statistical test for estimation of significance of the distance measure. The respective critical values depend only on the number of events and standard deviations of compared histograms and are not affected by distribution shape. Therefore, applications of QF do not require assumptions concerning distribution shape and can be easily implemented in practice. This notion was confirmed using empirical distributions of DNA content in plant tissue and distributions of immunofluorescence in human cells.
منابع مشابه
Comparison of Two Flow Cytometric Methods for Detection of Human Invariant Natural Killer T Cells (iNKT)
Background: Invariant natural killer cells (iNKT) are an important immunoregulatory T cell subset. Currently several flow cytometry-based approaches exist for the identifi-cation of iNKT cells, which rely on using the 6B11 monoclonal antibody or a combina-tion of anti-Vα24 and anti-Vβ11 antibodies. Objective: The aim of this study was to compare the ability of two flow cytometry-based methods f...
متن کاملflowCHIC - Analyze flow cytometric data of complex microbial communities based on histogram images
CHIC means cytometric histogram image comparison and is a tool for evaluation of cytometric datasets nearly automatically and very fast. CHIC neither requires gate setting procedures nor relies on quantification and binning of event distributions within histograms. The evaluation of histograms using CHIC is based on the main idea that histograms are converted into images thus working person ind...
متن کاملCytometric fingerprints: evaluation of new tools for analyzing microbial community dynamics
Optical characteristics of individual bacterial cells of natural communities can be measured with flow cytometry (FCM) in high throughput. The resulting data are visualized in cytometric histograms. These histograms represent individual cytometric fingerprints of microbial communities, e.g., at certain time points or microenvironmental conditions. Up to now four tools for analyzing the variatio...
متن کاملQuantitative Immunophemotyping of Platelet Surface Glycoproteins among Iranian Patients with Bernard-Soulier Syndrome
Background: Bernard-Soulier syndrome is a rare inherited bleeding disease caused by quantitative or qualitative defect of GPIb/IX/V, a platelet complex that binds the Von Willebrand factor. The expression of GPIb-IX-V complex can be evaluated by flow cytometry and confirmed by the absence of ristocetin-induced platelet aggregation in platelet-rich plasma. The main aim of the present study was t...
متن کاملAn Effective Approach for Robust Metric Learning in the Presence of Label Noise
Many algorithms in machine learning, pattern recognition, and data mining are based on a similarity/distance measure. For example, the kNN classifier and clustering algorithms such as k-means require a similarity/distance function. Also, in Content-Based Information Retrieval (CBIR) systems, we need to rank the retrieved objects based on the similarity to the query. As generic measures such as ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cytometry. Part A : the journal of the International Society for Analytical Cytology
دوره 73 8 شماره
صفحات -
تاریخ انتشار 2008