Recent Results from CVD-Diamond Heavy-Ion Detectors

نویسندگان

  • E. Berdermann
  • B. E. Fischer
  • M. Schlögl
  • H. Stelzer
  • B. Voss
چکیده

Latest results from radiation hardness measurements as well as single-particle pulse shape parameters, pulse-height distributions and time spectra are presented. An intrinsic time resolution of 29 ps is achieved with 52Cr ions of 650 MeV/amu and of 53 ps with 12C ions of 1.5 GeV/amu, respectively. The resolution is by 20% worse when increasing the beam intensity from 106 ions/s to 108 ions/s. Performing 58Ni fragmentation, collected charge distributions are measured in the range 15 < Z < 28. Whereas the S/N ratio improves about a factor of 2 the width of all spectra obtained is 70%. The same behaviour is found in 241Am-αdistributions increasing the electric field applied to the detector. In order to visualize and to quantify the influence of the electric field as well as of the total particle fluence to the charge-collection efficiency micro-beam measurements are performed with 12C ions of 5.9 MeV/amu stopped in the diamond bulk. Pulse-height spectra and charge-collection maps under different conditions are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Applications of CVD-Diamond Detectors in Heavy-ion Experiments

Test measurements with 241Am-α-particles, 12C, 20Ne, 58Ni, 208Pb and 238U projectiles are performed. It is shown that the most important charactristics of heavy-ion diamond detectors are described by the shaping parameters of the detectors single pulse. Distributions of rise and decay times of the signals as well as of the associated charge amplitudes are discussed. An intrinsic time resolution...

متن کامل

Characterisation of Single-Crystal CVD-Diamond Detectors

Recently, the quality of intrinsic CVD Diamond (CVD-D) has tremendously been improved. The replacement of the previous used silicon substrates for growth by ultra-pure HPHT Single-Crystal (SC) {100}-oriented diamond provides homo-epitaxial grown material almost free of structural defects. Nevertheless, all substrates nominally {100}oriented show a certain amount of off-angle declination from th...

متن کامل

Electrical and Photo Conductivities in Heteroepitaxial Quasi Single-Crystal CVD-Diamond Detectors

The properties of CVD Diamond (CVDD) detectors such as high mobility of charge carriers, radiation hardness, and low dark conductivity provide a detector material, which is suggested to be applied in high intensity heavy-ion beam environments where classical detector devices cannot be operated [1]. In the future FAIR experiments radiation-hard materials with large area will be required for a va...

متن کامل

Synthetic diamonds for heavy-ion therapy dosimetry

In this paper we report on first results obtained using polycrystalline CVD diamond detectors irradiated with heavily ionizing particles at GSI. At the UNILAC accelerator, ions with energies near the Bragg-Peak have been stopped inside the material whereas at the heavy-ion therapy facility of GSI these detectors are operated in transmission mode and have been studied in a carbon beam from SIS w...

متن کامل

The use of CVD-diamond for heavy-ion detection

The suitability of CVD-diamond detectors is investigated for applications in heavy-ion accelerator facilities with high intensity Ž . beams. Various diamond films of ‘optical’ and ‘electronic grade’ used and unpolished as grown are tested with different ions Ž241 . 208 238 from -particles Am-source up to the heaviest ions like Pb and U. The diamond signals are processed in a Ž . single-particle...

متن کامل

p-CVD diamond heavy-ion beam detector with integrated electronics

For the new ToF Barrel of FOPI, [1], a new beam detector based on polycrystalline-CVD diamond was developed. The new device replaces the existing beam monitoring system which comprise a ToF Start detector and a beam-halo detector, both built from plastic scintillator material. However, since the employed diamonds are not sensitive to minimum ionizing particles the new device can be used efficie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001