Measurements of Volatile Organic Compounds in a Newly Built Daycare Center
نویسندگان
چکیده
We measured temporal changes in concentrations of total volatile organic compounds (TVOCs) and individual volatile organic compounds in a newly built daycare center. The temporal changes of the TVOC concentrations were monitored with a photo ionization detector (PID), and indoor air was sampled and analyzed by Gas Chromatography/Mass Spectrometry (GC/MS) and high performance liquid chromatography (HPLC) to determine the concentrations of the constituent VOCs. The measurements were performed just after completion of the building and again 3 months after completion. The TVOC concentration exceeded 1000 µg·m(-3) for all the sampling locations just after completion of building, and decreased almost one tenth after 3 months, to below the guideline values of the TVOC in Japan at 400 µg·m(-3). The concentrations of the target VOCs of which the indoor concentrations are regulated in Japan were below the guideline values for all the cases. The air-exchange rates were determined based on the temporal changes of the TVOC concentrations, and it was found that the countermeasure to increase the air exchange rate successfully decrease the TVOC concentration level in the rooms.
منابع مشابه
Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...
متن کاملThe concentration of volatile organic compounds (VOCs) and related factors in the air in barbershops in Sanandaj in 2016
The aim of this study was to determine the density of benzene and toluene in barbershops of Sanandaj and also to determine effective factors for this pollution. A descriptive, analytical study was conducted to measure the volatile organic compound density and determine the effective factors. In this study, five hair salons and five barber shops were randomly selected from Sanandaj city. The vol...
متن کاملMathematical Modeling for Volatile Organic Compounds Removal in a Biofilter: Model Validation and Sensitivity Analysis
متن کامل
Estimation of volatile organic compounds in farmed and wild rohu, Labeo rohita
Volatile organic compounds in farmed and wild rohu, Labeo rohita, were extracted by Likens-Nickerson concurrent distillation apparatus. The farmed raised rohu of two weight categories designated as FW1 (1001-1200g) and FW2 (501-700g) were procured from the Fish Seed Hatchery, Faisalabad. Concurrently, wild rohu of two weight categories designated as WW1 (1001-1200g) and WW2 (501-700g) were capt...
متن کاملDevelopment of a Method Based on the Needle-trap Microextraction Filled with Hydroxyapatite and Polyaniline Nanocomposite for Determination of Volatile Organic Compounds in the Air
In this study, the efficiency of packed needle trap with hydroxyapatite/polyaniline (NTD-HAP/PA) nanocomposite was assessed in air sampling and analysis of a hazardous group of VOCs such as benzene, toluene, ethylbenzene and xylenes. The effects of main parameters, including desorption temperature and time, were evaluated on the performance and carryover of prepared NTDs. Moreover, the repeatab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2016