Laser refractive surgery for myopia increases the eye's higher-order wavefront aberrations (HOA's). However, little is known about the impact of such optical degradation on post-operative image quality (IQ) of these eyes. This study determined the relation between HOA's and IQ parameters (peak IQ, dioptric focus that maximized IQ and depth of focus) derived from psychophysical (logMAR acuity) and computational (logVSOTF) through-focus curves in 45 subjects (18 to 31 yrs) before and 1-month after refractive surgery and in 40 age-matched emmetropic controls. Computationally derived peak IQ and its best focus were negatively correlated with the RMS deviation of all HOA's (HORMS) (r≥-0.5; p<0.001 for all). Computational depth of focus was positively correlated with HORMS (r≥0.55; p<0.001 for all) and negatively correlated with peak IQ (r≥-0.8; p<0.001 for all). All IQ parameters related to logMAR acuity were poorly correlated with HORMS (r≤|0.16|; p>0.16 for all). Increase in HOA's after refractive surgery is therefore associated with a decline in peak IQ and a persistence of this sub-standard IQ over a larger dioptric range, vis-à-vis, before surgery and in age-matched controls. This optical deterioration however does not appear to significantly alter psychophysical IQ, suggesting minimal impact of refractive surgery on the subject's ability to resolve spatial details and their tolerance to blur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoastigmatic refractive keratectomy for compound myopic astigmatism with a Nidek laser.

BACKGROUND With advances in the delivery of excimer laser energy to the cornea, spherocylindrical ablations are now possible. The refractive and visual outcome of eyes undergoing photoastigmatic refractive keratectomy with a minimum of 12 months follow-up are presented. METHODS A retrospective analysis of 160 consecutive eyes that underwent photoastigmatic refractive keratectomy using the Nid...

متن کامل

Effect of beam size on the expected benefit of customized laser refractive surgery.

PURPOSE Customized laser surgery attempts to correct higher order aberrations, as well as defocus and astigmatism. The success of such a procedure depends on using a laser beam that is small enough to produce fine ablation profiles needed to correct higher order aberrations. METHODS Wave aberrations were obtained from a population of 109 normal eyes and 4 keratoconic eyes using a Shack-Hartma...

متن کامل

Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).

PURPOSE This study tests the hypothesis that the keratometric value derived from Orbscan II mean power maps, when used in an intraocular lens (IOL) calculation formula, at a specific measurement zone, will accurately determine the power of an IOL for planned cataract surgery in patients who have undergone prior myopic laser-assisted in situ keratomileusis (LASIK). METHODS This is a two-part s...

متن کامل

Effect of limbal marking prior to laser ablation on the magnitude of cyclotorsional error.

PURPOSE To evaluate the residual registration error after limbal-marking-based manual adjustment in cyclotorsional tracker-controlled laser refractive surgery. METHODS Two hundred eyes undergoing custom surface ablation with the iVIS Suite (iVIS Technologies) were divided into limbal marked (marked) and non-limbal marked (unmarked) groups. Iris registration information was acquired preoperati...

متن کامل

Optical quality after myopic photorefractive keratectomy and laser in situ keratomileusis: comparison using a double-pass system.

PURPOSE To use a double-pass system to compare the optical quality after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) for mild to moderate myopia. SETTING Universitat Politècnica de Catalunya, Terrassa, Barcelona Institute of Ocular Microsurgery, Barcelona, Spain. DESIGN Comparative case series. METHODS Optical quality was assessed with a clinical double-pass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016