Bounds on the Accuracy of the Reduced-Load Blocking Formula in Some Simple Circuit-Switched Networks
نویسندگان
چکیده
Circuit switched communication networks are considered in which each route is two links long, and each link can carry one call at a time. No symmetry assumption is made. Simple bounds, depending on the maximum call arrival rate and the maximum sum of rates at a link, are given on the blocking probabilities. An implication is that if the maximum perroute arrival rate converges to zero with a fixed bound on the sum of rates at links, then the well known reduced-load blocking approximation is asymptotically exact, uniformly over all network topologies.
منابع مشابه
Design, Construction and Comparison of a Sensorless Driver Circuit for Switched Reluctance Motor
In the presented paper, a sensorless driver circuit is designed, constructed and tested to control two types of three-phase Switched Reluctance Motor (SRM). The presented control algorithm has three steps. In the first step, the SRM is controlled by an open-loop method. In the second step, mathematical model of the SRM phase, motor parameters and flux-current-rotor position relation are used in...
متن کاملA High Gain Bipolar Pulse Generator with Low Voltage Input Source
This paper proposes a pulsed power generator which consists of two types of switched-capacitor booster modules. A doubling mode module employed to elevate the input voltage to a specified level and, constant mode module is used to increase the elevated voltage into the finally intended bipolar output voltage. Also, the proposed modular structure does not utilize any switches across the load. Ot...
متن کاملInvestigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment
Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...
متن کاملan Efficient Drive Circuit for Switched Reluctance Motor
The purpose of this paper is to present an efficient converter circuit used to drive switched reluctance motors. It uses the C-dump topology in which the trapped energy in the phase windings is returned to the supply capacitor to be used in the following strokes. In addition to the C-dump topology, it uses two extra feedbacks. One comes from a governor mounted on the shaft of motor which contro...
متن کاملTransient Minimization Within Static Var Compensated Distribution Systems
VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006