Metamaterial endoscope for magnetic field transfer: near field imaging with magnetic wires.

نویسندگان

  • Michael Wiltshire
  • J Hajnal
  • J Pendry
  • D Edwards
  • C Stevens
چکیده

We report on the development and use of a highly anisotropic magnetic metamaterial for near-field imaging. The material consists of an array of Swiss Roll structures, resonant near 21.3 MHz, with a peak value of relative permeability ~35. At this peak, the material transfers an input magnetic field pattern to the output face without loss of intensity and with a spatial resolution equal to the roll diameter. It behaves as a near-field imaging device consisting of a bundle of magnetic wires.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study of turbulent free convection of liquid metal with constant and variable properties in the presence of magnetic field

In this research, turbulent MHD convection of liquid metal with constant and variable properties is investigated numerically. The finite volume method is applied to model the fluid flow and natural convection heat transfer in a square cavity. The fluid flow and heat transfer were simulated and compared for two cases constant and variable properties. It is observed that for the case variable pro...

متن کامل

Tunable negative index metamaterial using yttrium iron garnet

A magnetic field tunable, broadband, low-loss, negative refractive index metamaterial is fabricated using yttrium iron garnet (YIG) and a periodic array of copper wires. The tunability is demonstrated from 18 to 23GHz under an applied magnetic field with a figure of merit of 4.2GHz/kOe. The tuning bandwidth is measured to be 5GHz compared to 0.9GHz for fixed field. We measure a minimum insertio...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Effects of variations in magnetic Reynolds number on magnetic field distribution in electrically conducting fluid under magnetohydrodynamic natural convection

In this study the effect of magnetic Reynolds number variation on magnetic distribution of natural convection heat transfer in an enclosure is numerically investigated. The geometry is a two dimensional enclosure which the left wall is hot, the right wall is cold and the top and bottom walls are adiabatic. Fluid is molten sodium with Pr=0.01 and natural convection heat transfer for Rayleigh num...

متن کامل

Investigating the effect of magnetic field on the forced convection of cross-corrugated triangular channels

Cross-corrugated triangular channels increase heat transfer in heat exchangers. The mixing effect increases the heat transfer coefficient at the surfaces. In this study, the fluid flow and heat transfer in a triangular corrugated channel are modeled under two constant heat fluxes and different Reynolds numbers. In order to validate, k-ω turbulence model is used. Also, the effect of magnetic fie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 11 7  شماره 

صفحات  -

تاریخ انتشار 2003