EER Improvement for Room Air-Conditioners in Saudi Arabia

نویسنده

  • Abdullah M. Al-Shaalan
چکیده

This paper demonstrates the possibility of achieving a higher Energy Efficiency Ratio (EER) for Room Air Conditioners (RACs) that complies with the Saudi energy efficiency standards and satisfies the energy conservation requirements for the Saudi Building Code (SBC). This study considers several design options for improving the performance and efficiency of the RAC in comparison with a baseline RAC unit manufactured by Al-Zamil Company of Saudi Arabia. These design options include the number of condenser and evaporator rows, fins density, frontal area, compressor types, and refrigerant types. The experimental data obtained is through testing the units in Calorimeter according to standard ASHRAE-16. Also, the uncertainty in measurements and its propagation are included in this study. This paper reports the results of a set of measurements carried out on a modified RAC and compares them with the tested baseline RAC unit at similar load conditions. The experimental results indicate the effectiveness of increasing the number of condenser rows in comparison with other design options considered for achieving higher EER for RACs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reform in Accounting Standards: Evidence from Saudi Arabia

Middle East countries have begun to implement economic reforms to stimulate private investment, promote economic growth and support the transition to market economy. Although, it is difficult to define the direct impact of the accounting system reform on economic transformation, as there are many other conditions that have influence on the transition process. However, with the central position ...

متن کامل

A simple and safe method for preparation of Mg(OH)2 nanorods in ambient air

Magnesium hydroxide Mg(OH)2 nanorods with diameters of 90±10nm and lengths of more than 2μms were prepared by a simple route at ~75oC in ambient air. The approach is based on reaction of magnesium powder and de-ionized water without the use of any harmful, toxic or corrosive reagents. Characterization using X-ray diffraction (XRD) shows single crystalline structure of Mg(O...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Home Thermal Modeling: Cooling Energy Consumption and Costs in Saudi Arabia

Objectives: The consumption of electricity and its costs are expected to be increased in Saudi Arabia due to its rapid growth in population. As the Kingdom is characterized by extreme hot climate, a massive amount of electricity consumed by the residential sector goes to power air conditioners. To control this huge amount of energyconsumedin homes, thermal models have been generated with two or...

متن کامل

Design and Experimentation of Roll Bond Evaporator for Room Air Conditioner with R-22 as Refrigerant

The world is looking towards producing products which consume less power without compromising on quality of life. The increase in use of refrigeration and air conditioning appliances are contributing to global warming. The world wide temperatures are shooting up at an increasing rate. This paper presents a design of roll bond evaporator as the heat exchanger to provide cooling in room air condi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013