Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings
نویسندگان
چکیده
BACKGROUND Although premature beats are a matter of concern in horses, the interpretation of equine ECG recordings is complicated by a lack of standardized analysis criteria and a limited knowledge of the normal beat-to-beat variation of equine cardiac rhythm. The purpose of this study was to determine the appropriate threshold levels of maximum acceptable deviation of RR intervals in equine ECG analysis, and to evaluate a novel two-step timing algorithm by quantifying the frequency of arrhythmias in a cohort of healthy adult endurance horses. RESULTS Beat-to-beat variation differed considerably with heart rate (HR), and an adaptable model consisting of three different HR ranges with separate threshold levels of maximum acceptable RR deviation was consequently defined. For resting HRs <60 beats/min (bpm) the threshold level of RR deviation was set at 20%, for HRs in the intermediate range between 60 and 100 bpm the threshold was 10%, and for exercising HRs >100 bpm, the threshold level was 4%. Supraventricular premature beats represented the most prevalent arrhythmia category with varying frequencies in seven horses at rest (median 7, range 2-86) and six horses during exercise (median 2, range 1-24). CONCLUSIONS Beat-to-beat variation of equine cardiac rhythm varies according to HR, and threshold levels in equine ECG analysis should be adjusted accordingly. Standardization of the analysis criteria will enable comparisons of studies and follow-up examinations of patients. A small number of supraventricular premature beats appears to be a normal finding in endurance horses. Further studies are required to validate the findings and determine the clinical significance of premature beats in horses.
منابع مشابه
Age-dependent electrocardiographic and echocardiographic changes in German Shepherd dogs
By causing numerous changes in the cardiovascular system, ageing leads to a decreased threshold for clinical manifestation of heart disease. The aim of this study was to define the existence of cardiac structural and functional changes in healthy dogs of different age. Radiographic, electrocardiographic (ECG) and echocardiographic examinations of 20 clinically healthy German Shepherd dogs were ...
متن کاملEffect of endotoxemia on heart rate dynamics in rat isolated perfused hearts
Introduction: Beat-to-beat variation in heart rate shows a complex dynamics, and this complexity is changed during systemic inflammatory response syndrome (e.g. sepsis). It is not known whether or not cardiac pacemaker dynamical rhythm is affected by sepsis. The aim of this study was to investigate heart rate dynamics of isolated heart as well as expression of pacemaker channels (HCN) in a r...
متن کاملA Simple and User friendly tool for determining R-R intervals from the time series data of Electrocardiogram
Heart rate is a non-stationary signal and varies continuously in health and in disease. The pattern alteration in its variation contains indicators of current or impending diseases. Heart rate variability (HRV), a popular noninvasive tool is the variation over timeperiod between consecutive heartbeats. It assesses the activities of the autonomic nervous system and is highly useful in diagnostic...
متن کاملCardiac Arrhythmia Classification Using Support Vector Machines
A method for automatic arrhythmic beat classification is proposed. The method is based in the analysis of the RR interval signal, extracted from ECG recordings. Classification is made using support vector machines methodology to formulate a quadratic programming problem, subject to simple constraints, which is solved using the BOXCQP method. Four types of cardiac rhythms beats are classified: (...
متن کاملAn ischemia detection method based on artificial neural networks
An automated technique was developed for the detection of ischemic episodes in long duration electrocardiographic (ECG) recordings that employs an artificial neural network. In order to train the network for beat classification, a cardiac beat dataset was constructed based on recordings from the European Society of Cardiology (ESC) ST-T database. The network was trained using a Bayesian regular...