Real-time observation of reactive spreading of gold on silicon.

نویسندگان

  • Nicola Ferralis
  • Farid El Gabaly
  • Andreas K Schmid
  • Roya Maboudian
  • Carlo Carraro
چکیده

The spreading of a bilayer gold film propagating outward from gold clusters, which are pinned to clean Si(111), is imaged in real time by low-energy electron microscopy. By monitoring the evolution of the boundary of the gold film at fixed temperature, a linear dependence of the spreading radius on time is found. The measured spreading velocities in the temperature range of 800 < T < 930 K varied from below 100 pm/s to 50 nm/s. We show that the spreading rate is limited by the reaction to form Au silicide, and the spreading velocity is likely regulated by the reconstruction of the gold silicide that occurs at the interface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

همبستگی تخلخل با زبری توسط طیف پراکندگی سطوح نانویی سیلیکان متخلخل

Reflection spectra of four porous silicon samples under etching times of 2, 6, 10, and 14 min with current density of 10 mA/cm2 were measured. Reflection spectra behaviors for all samples were the same, but their intensities were different and decreased by increasing the etching time. The similar behavior of reflection spectra could be attributed to the electrolyte solution concentration which ...

متن کامل

Optical properties of silicon nano layers by using Kramers- Kronig method

Silicon thin layers are deposited on glass substrates with the thickness of 103 nm, 147 nm and 197 nm. The layers are produced with electron gun evaporation method under ultra-high vacuum condition. The optical Reectance and the Transmittance of produced layers were measured by using spectrophotometer. The optical functions such as, real and imaginary part of refractive index, real and imaginar...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Evaluation of Microscopy Sensitivity, Specificity in Detection of P. falciparum and P. vivax, Using Monoplex real-time PCR, Gezira, Sudan

Background: Malaria is still account for 200 million cases annually. Microscopy is the gold standard technique for malaria parasites detection. PCR-based techniques can detect malaria infections with high sensitivity. The study aimed to evaluate the sensitivity of microscopy technique in the detection of P. falciparum and P. vivax, using monoplex real-time PCR, Gezira State, Central Sudan. Met...

متن کامل

Substrate Effeci’s on the Surface Topography of Eva~~~d Gold Films - a Scanning Knelling Microscopy Investigation

Direct observation of surface roughness on metal films is a longstanding problem in thin film characte~tion. In this work the high quality of scanning tunnelhng microscopy (STM) was used for investigation of evaporated gold films. A scanning tunnel&g microscope able to scan areas up to 0.8 x 0.8 pm with high reproducibility is presented. The topography of 80 nm thick gold films grown under iden...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 103 25  شماره 

صفحات  -

تاریخ انتشار 2009