The correlation between IOP measurement, central corneal thickness and corneal curvature.
نویسندگان
چکیده
In a prospective study we measured the intraocular pressure (IOP), the central corneal thickness (CCT) and the central corneal curvature in 172 myopic eyes before and after LASIK treatment. We find a significant decrease in intraocular pressure. Statistical evaluation reveals a linear correlation between the IOP decrease and the amount of stromal ablation. The IOP and corneal curvature are measured in 21 hyperopic eyes before and after LASIK treatment. We do not find a change in the IOP. In a retrospective study of 47 myopic eyes before and after RADIAL KERATOTOMY we find no change in IOP. We conclude that CCT is important in evaluating the IOP and that corneal curvature has little effect on IOP measurement.
منابع مشابه
بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کامل[Correlation between intraocular pressure, paquimetry and keratometry in a normal population].
PURPOSE To study the intraocular pressure (IOP), the corneal thickness and the corneal curvature distribution in a normal population. To investigate the relation between these variables, and to determine if the IOP and the paquimetry will be modified by the refractive error and age. METHODS A population of 273 subjects, 545 eyes, without ocular pathology was selected. The refractive error, th...
متن کاملThe Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature
The purpose of the study was to investigate the correlation between Corneal Visualization Scheimpflug Technology (Corvis ST tonometry: CST) parameters and various other ocular parameters, including intraocular pressure (IOP) with Goldmann applanation tonometry. IOP with Goldmann applanation tonometry (IOP-G), central corneal thickness (CCT), axial length (AL), corneal curvature, and CST paramet...
متن کاملGoldmann tonometer error correcting prism: clinical evaluation
PURPOSE Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. METHODS A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness,...
متن کاملIntraocular pressure in a cohort of healthy eastern European schoolchildren: variations in method and corneal thickness
BACKGROUND Intraocular pressure (IOP) in the developing eye of a child is not always easy to measure and there is no technique that is known to be the most accurate for the young eye. Measurements are needed on many cohorts of children with different tonometers to determine how the values correlate between instruments, whether corneal parameters affect readings and whether correlations between ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bulletin de la Societe belge d'ophtalmologie
دوره 276 شماره
صفحات -
تاریخ انتشار 2000