New Wavenumber Calibration Tables From Heterodyne Frequency Measurements
نویسندگان
چکیده
This new calibration atlas is based on frequency rather than wavelength calibration techniques for absolute references. Since a limited number of absolute frequency measurements is possible, additional data from alternate methodology are used for difference frequency measurements within each band investigated by the frequency measurements techniques. Data from these complementary techniques include the best Fourier transform measurements available. Included in the text relating to the atlas are a description of the heterodyne frequency measurement techniques and details of the analysis, including the Hamiltonians and least-squares-fitting and calculation. Also included are other relevant considerations such as intensities and lincshape parameters. A 390-entry bibliography which contains all data sources used and a subsequent section on errors conclude the text portion. The primary calibration molecules are the linear triatomics, carbonyl sulfide and nitrous oxide, which cover portions of the infrared spectrum ranging from 488 to 3120 cm-1. Some gaps in the coverage afforded by OCS and N2O are partially covered by NO, CO, and CS2. An additional region from 4000 to 4400 cm-1 is also included. The tabular portion of the atlas is too lengthy to include in an archival journal. Furthermore, different users have different requirements for such an atlas. In an effort to satisfy most users, we have made two different options available. The first is NIST Special Publication 821, which has a spectral map/facing table format. The spectral maps (as well as the facing tables) are calculated from molecular constants derived for the work. A complete list of all of the molecular transitions that went into making the maps is too long (perhaps by a factor of 4 or 5) to include in the facing tables. The second option for those not interested in maps (or perhaps to supplement Special Publication 821) is the complete list (tables-only) which is available in computerized format as NIST Standard Reference Database #39, Wavelength Calibration Tables.
منابع مشابه
Phase calibration of hydrophones: heterodyne time-delay spectrometry and broadband pulse technique using an optical reference hydrophone
Two hydrophone calibration techniques are presented which provide amplitude and phase of hydrophone sensitivity. Heterodyne time-delay spectrometry can be applied in the frequency range from 0.5 to 50 MHz to all common hydrophones but needs a standard to obtain absolute values. A pulse technique between 1 and 70 MHz allows exploiting of an optical multilayer hydrophone as a phase standard. In c...
متن کاملAbsolute Calibration of Hydrophones Using Heterodyne Interferometry and Zero-crossing Signal Demodulation
The current primary method for hydrophone calibration is the three-transducer spherical-wave reciprocity at NPL, covering the frequency range between 1 kHz up to 500 kHz with expanded uncertainties as low as ± 0.5 dB. Optical methods can provide an alternative method for primary calibration as they directly measure the acoustic particle velocity at a specific point in the field. The hydrophone ...
متن کاملSignal Processing for High Precision Phase Measurements*
High precision phase measurement is important for many areas of accelerator operation. In a heterodyne digital receiver, one source of phase error is the thermal variation of the input stage. We have developed a technique to calibrate this drift. A CW calibration signal is sent through the same components together with the RF signal to measure and compensate the component drift. At intermediate...
متن کاملInitial ground-based thermospheric wind measurements using Doppler asymmetric spatial heterodyne spectroscopy (DASH).
We present the first thermospheric wind measurements using a Doppler Asymmetric Spatial Heterodyne (DASH) spectrometer and the oxygen red-line nightglow emission. The ground-based observations were made from Washington, DC and include simultaneous calibration measurements to track and correct instrument drifts. Even though the measurements were made under challenging thermal and light pollution...
متن کاملFrequency Response Measurement of Digital Communications Analyzer Plug-in Modules
It has been extremely difficult to characterize the SONET/SDH standard receiver with tolerances of 0.3 dB. This paper describes a method for calibrating photoreceiver frequency response with the low inherent uncertainty of the U.S. National Institute of Standards and Technology Nd:YAG heterodyne system and transferring this calibration to a production test system while maintaining a low uncerta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 97 شماره
صفحات -
تاریخ انتشار 1992