چکیده

The absolute frequency of the length standard at 514.67 nm based on the molecular iodine ( I2) transition of the P(13) 43-0 component a3 is measured using a self-referenced femtosecond optical comb. This frequency-based technique improves measurement precision more than 100 times compared with previous wavelength-based results. Powerand pressure-related frequency shifts have been carefully studied. The measured absolute frequency is 71.8±1.5 kHz higher than the internationally accepted value of 582 490 603.37±0.15 MHz, adopted by the Comité International des Poids et Mesures (CIPM) in 1997. PACS 06.20.-f; 06.20.Fn; 06.30.Bp; 06.30.Ft

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absolute Frequency Measurement of the Iodine-Stabilized Heâ‹TMNe Laser at 633 Nm

The absolute frequency of an iodine-stabilized He−Ne laser at 633 nm stabilized on the i (or a13) component of the 11-5 R(127) hyperfine transition of the I2 molecule is measured using a femtosecond optical comb generator and an iodine-stabilized Nd:YAG laser standard at 1064 nm. We link the measured absolute frequency to the current internationally adopted value via frequency intercomparison b...

متن کامل

Accuracy comparison of absolute optical frequency measurement between harmonic-generation synthesis and a frequency-division femtosecond comb

Using an iodine-stabilized He-Ne laser as a transfer oscillator, we compare absolute measurements of the optical frequency from a traditional frequency synthesis chain based on harmonic generation and from the frequency division technique of an ultrawide bandwidth femtosecond frequency comb. The agreement between these two measurements, both linked to the Cs standard, is 220+/-770 Hz, yielding ...

متن کامل

TRACEABILITY OF 633 nm LASER CALIBRATION AT NIMT

− The National Institute of Metrology (Thailand), NIMT, maintains the standard of length in accordance with the definition of the meter through a 633 nm iodine stabilized He-Ne laser. Its accuracy is transferred to stabilized and non-stabilized lasers regarding to beatfrequency method and direct measurement using a wavelength meter, respectively. The traceability in wavelength measurement at th...

متن کامل

Measurement of Iodine Cell Purity and Absolute Frequency Shifts for Laser Stabilization

− This contribution deals with the investigation of uncertainties achievable through stabilization of lasers using saturated absorption in iodine vapour. The main focus is on the iodine cell technology and evaluation. We present results from two independent methods for the measurement of the purity of molecular iodine in absorption cells. The purity was tested by improved method based on measur...

متن کامل

Space interferometry application of laser frequency stabilization with molecular iodine.

A number of planned space interferometry missions, including the Laser Interferometer Space Antenna (LISA) gravitational wave detector, require a laser system with high-frequency stability over long time scales. A 1064 nm wavelength nonplanar ring oscillator (NPRO) laser stabilized to a resonant transition in molecular iodine is suitable for these missions, providing high-frequency stability at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015