Stable isotope-dilution GC MS for the quantification of food contaminants

نویسنده

  • James R. Startin
چکیده

The data obtained from the analyses of the samples described above were used to develop response surface equations which would predict the effect of the irradiation dose and temperature on each vitamin over the entire area covered by the design. From the equation for the response surface for thiamin loss the predicted losses in pork chops irradiated at 0 'C and then cooked were as follows: 0 kGy, -1.5% (-0.04%); 0.50 kGy, -10.1% (14.3%); 3.5 kGy, -48.7% (54.3%); and 7.0 kGy, -65.9% (69.7%). The values given in parentheses represent the average of the actual observed values. There was no loss of thiamin in the control on a sample weight basis upon cooking, but there was an overall weight loss of about 30%. The effect of temperature on the degradation of thiamin can be illustrated by comparison of the predicted results obtained at a dose of 3.5 kGy, losses of 32.7 (34.9%) and 63.3% (60.2%) at -20' and +20'C respectively. The fit of the predicted values to the measured values is indicated by a R' value of 0.90 for the equation for the response surface. The effect of radiation on thiamin was different in poultry from that observed in pork. The response surface equation for thiamin loss in chicken breasts cooked after irradiation predicted the following losses of thiamin at 0 'C: 0 kGy, + 3.2%; 1.0 kGy, -0.38%; 2.0 kGy, -2.2%; 3.0 kGy, -5.9%; 3.5 kGy, -7.4%; and 7.0 kGy, -34.9%. Thus, in the range of greatest interest for the control of salmonella contamination (3.0 kGy) the loss of thiamin was very low especially when compared to losses in pork chops irradiated and cooked in the same manner.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous analysis of phthalates, adipate and polycyclic aromatic hydrocarbons in edible oils using isotope dilution-gas chromatography-mass spectrometry.

A method for simultaneous determination of 12 priority phthalates, adipate and polycyclic aromatic hydrocarbons (PAHs) in edible oils by isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) was developed for fast, accurate and trace analysis. The extraction and clean-up procedures were optimised, and using stable isotope-labelled internal standards for each analyte, relative standar...

متن کامل

EU marker polycyclic aromatic hydrocarbons in food supplements: analytical approach and occurrence

Several food supplements comprising botanical, oil and bee products collected from retail markets in different countries were tested for the occurrence of 4 EU marker Polycyclic aromatic hydrocarbons (PAHs; benz[a]anthracene, chrysene, benzo[b]fluoranthene and benzo[a]pyrene). A robust GC/MS-based stable-isotope dilution method was used taking into account the differences in the type of matrice...

متن کامل

Application of isotope dilution mass spectrometry: determination of ochratoxin A in the Canadian Total Diet Study

Analytical methods are generally developed and optimized for specific commodities. Total Diet Studies, representing typical food products 'as consumed', pose an analytical challenge since every food product is different. In order to address this technical challenge, a selective and sensitive analytical method was developed suitable for the quantitation of ochratoxin A (OTA) in Canadian Total Di...

متن کامل

Yield effects on 2-methoxy-3-isobutylpyrazine concentration in cabernet sauvignon using a solid phase microextraction gas chromatography/mass spectrometry method.

A rapid and automated solid phase microextraction (SPME) stable isotope dilution gas chromatography/mass spectrometry (GC-MS) method for 2-methoxy-3-isobutylpyrazine (MIBP) quantification in red wine was developed. Wines with 30% (w/v) NaCl and 2-methoxy-(2)H(3)-3-isobutylpyrazine internal standard were sampled with a 2 cm divinylbenzene/carboxen/poly(dimethylsiloxane) SPME fiber for 30 min at ...

متن کامل

Isotope dilution gas chromatographic-mass spectrometric measurement of tricyclic antidepressant drugs. Utility of the 4-carbethoxyhexafluorobutyryl derivatives of secondary amines.

Stable isotope dilution gas chromatographic-mass spectrometric (GC-MS) measurement of tricyclic antidepressants (TCA) is a useful alternative to high-performance liquid chromatography (HPLC) methods when interfering substances prevent accurate quantitation by HPLC. For satisfactory GC-MS analysis, secondary amine TCA must be derivatized. Commonly employed trifluoroacetyl and heptafluorobutyryl ...

متن کامل

GC/CI-MS/MS method for the identification and quantification of volatile N-nitrosamines in meat products.

A sensitive and selective method was developed and validated for the determination of nine N-nitrosamines in meat products. The N-nitrosamines were extracted with NaOH/methanol, partitioned into dichloromethane on a ChemElut column and cleaned-up by solid-phase extraction. All samples were spiked with (2)H isotope-labelled N-nitrosamine internal standard prior to extraction. After purification ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010