Validity of a new computer-aided diagnosis imaging program to quantify nuclear cataract from slit-lamp photographs.
نویسندگان
چکیده
PURPOSE To validate a new computer-aided diagnosis (CAD) imaging program for the assessment of nuclear lens opacity. METHODS Slit-lamp lens photographs from the Singapore Malay Eye Study (SiMES) were graded using both the CAD imaging program and manual assessment method by a trained grader using the Wisconsin Cataract Grading System. Cataract was separately assessed clinically during the study using Lens Opacities Classification System III (LOCS III). The repeatability of CAD and Wisconsin grading methods were assessed using 160 paired images. The agreement between the CAD and Wisconsin grading methods, and the correlations of CAD with Wisconsin and LOCS III were assessed using the SiMES sample (5547 eyes from 2951 subjects). RESULTS In assessing the repeatability, the coefficient of variation (CoV) was 8.10% (95% confidence interval [CI], 7.21-8.99), and the intraclass correlation coefficient (ICC) was 0.96 (95% CI, 0.93-0.96) for the CAD method. There was high agreement between the CAD and Wisconsin methods, with a mean difference (CAD minus Wisconsin) of -0.02 (95% limit of agreement, -0.91 and 0.87) and an ICC of 0.81 (95% CI, 0.80-0.82). CAD parameters were also significantly correlated with LOCS III grading (all P < 0.001). CONCLUSIONS This new CAD imaging program assesses nuclear lens opacity with results comparable to the manual grading using the Wisconsin System. This study shows that an automated, precise, and quantitative assessment of nuclear cataract is possible.
منابع مشابه
Grading nuclear cataract: reproducibility and validity of a new method.
AIMS To assess the reproducibility and validity of a new instrument for grading nuclear cataract-the laser slit lamp, by comparison with an established method of lens grading-the Lens Opacities Classification System III (LOCS III). METHODS 62 volunteers (113 eyes) were examined on two occasions. At each visit, a video image of the anterior segment was captured with the laser slit lamp and sto...
متن کاملThe effect of cataract severity and morphology on the reliability of the Lens Opacities Classification System II (LOCS II).
Data collected from 3646 eyes in the Italian-American Natural History Study of Age-Related Cataract were used to investigate whether the reliability of the Lens Opacities Classification System II (LOCS II) by the severity of the opacity that is being graded or is influenced by the presence and severity of coexisting opacities. Reliability was assessed by comparing the slit-lamp gradings of two ...
متن کاملUse of photographic techniques to grade nuclear cataracts.
Methods for objectively documenting and grading different varieties of lens opacities are needed in order to conduct research on risk factors for cataracts. This study tested the feasibility and reliability of using two different photographic methods to grade nuclear opacities. Photographs were taken of 41 eyes using a regular Topcon SL-5D photo slit lamp, and using a Topcon SL-45 (Scheimpflug)...
متن کاملNuclear cataract shows significant familial aggregation in an older population after adjustment for possible shared environmental factors.
PURPOSE To quantify the association between siblings in age-related nuclear cataract, after adjusting for known environmental and personal risk factors. METHODS All participants (probands) in the Salisbury Eye Evaluation (SEE) project and their locally resident siblings underwent digital slit lamp photography and were administered a questionnaire to assess risk factors for cataract including:...
متن کاملImage based grading of nuclear cataract by SVM regression
Cataract is one of the leading causes of blindness worldwide. A computer-aided approach to assess nuclear cataract automatically and objectively is proposed in this paper. An enhanced Active Shape Model (ASM) is investigated to extract robust lens contour from slit-lamp images. The mean intensity in the lens area, the color information on the central posterior subcapsular reflex, and the profil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 3 شماره
صفحات -
تاریخ انتشار 2011