Transection with pseudoaneurysm formation of the pulmonary trunk after placement of an adjustable pulmonary artery banding device (FloWatch-PAB) in a patient with residual muscular ventricular septal defect.

نویسندگان

  • Prem S Venugopal
  • Nicholas Hayes
  • John Simpson
  • David Anderson
چکیده

FIGURE 1. Two-dimensional echocardiographic analysis with Doppler scann artery (PA) band device in the lumen of the pulmonary artery. RA, Right atrium From Congenital Heart Surgery, Guy’s & St Thomas NHS Foundation Trust, London, United Kingdom. Disclosures: None. Received for publication Jan 20, 2009; revisions received Feb 7, 2009; accepted for publication March 2, 2009; available ahead of print May 18, 2009. Address for reprints: Prem S. Venugopal, MCh, FRCS, Congenital Heart Surgery, Guy’s & St Thomas NHS Foundation Trust, 20, Stangate, Royal St, London SE1 7EQ, United Kingdom (E-mail: [email protected]). J Thorac Cardiovasc Surg 2010;139:e103-4 0022-5223/$36.00 Copyright 2010 by The American Association for Thoracic Surgery doi:10.1016/j.jtcvs.2009.03.002

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Telemetrically adjustable pulmonary artery banding: first application in Greece.

We describe the first application in Greece of a telemetrically adjustable device for pulmonary artery banding (FloWatch-PAB device) in a 2-month-old baby, weighing 3.6 kg, with congenital heart disease (complete atrioventricular septal defect with pulmonary hypertension). The surgical application of the device was easy, the postoperative course of the patient was smooth, and the telemetric reg...

متن کامل

Early clinical results of the telemetric adjustable pulmonary artery banding FloWatch-PAB.

BACKGROUND Adjustment of pulmonary artery banding (PAB) may be a challenging procedure in complex congenital heart defects. Whatever the technique used, subsequent re-operations are frequently needed to control the pulmonary blood flow or pressures. OBJECTIVE To report the efficacy of a new telemetric adjustable PAB (FloWatch-PAB) operated with the help of an external control unit that transm...

متن کامل

Multiple Ventricular Septal Defects: A New Strategy

INTRODUCTION A multicenter prospective study was conducted to evaluate a new strategy for multiple Ventricular Septal Defects (VSDs). MATERIALS AND METHODS From 2004 to 2012 17 consecutive children (3 premature, 14 infants), mean age 3.2 months (9 days-9 months), mean body weight 4.2 kg (3.1-6.1 kg), with multiple VSDs underwent Pulmonary Artery Banding (PAB) with an adjustable FloWatch-PAB(®...

متن کامل

Use of a new implantable adjustable pulmonary artery banding device: a report of two patients.

Pulmonary artery banding (PAB) is a method for reducing pulmonary artery blood flow and pressure by tying a surgical band around the main pulmonary artery (MPA). Originally, the procedure was primarily performed to palliate intracardiac left to right shunts for ventricular septal defects (VSDs). Currently, the use of PAB has expanded to allow it to be used in ventricular training, prior to tota...

متن کامل

Indications, Results and Mortality of Pulmonary Artery Banding Procedure: a Brief Review and Five- year Experiences

Background Pulmonary artery banding (PAB) is a technique of palliative surgical therapy used by congenital heart surgeons as a staged approach to operative correction of congenital heart defects. Materials and Methods We report 5- year experiences from January 2011 to January 2016 of Imam Reza Hospital center (a tertiary referral hospital in Mashhad city, North East of Iran) that consist of 50 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 139 5  شماره 

صفحات  -

تاریخ انتشار 2010