Contamination of Qiagen DNA extraction kits with Legionella DNA.
نویسندگان
چکیده
van der Zee and Crielaard recently reported the contamination of Qiagen DNA extraction columns with Legionella species (6). We have independently made this discovery and have attempted to further characterize the contaminating DNA. We used the Qiagen columns (QIAamp DNA minikit; Qiagen, Hilden, Germany) for the extraction of DNA from a variety of clinical samples to be tested for Legionella DNA by PCR. When PCR assays targeting the Legionella 16S rRNA gene (1) or 5S rRNA gene (2) were used, positive signals were frequently recorded for the negative controls. The 5S rRNA amplicon contained a single TaqI restriction site, a characteristic of Legionella spp. that we have used to confirm the specificity of the PCR assay (2). Investigation of all potential sources of contamination indicated that the columns were the source and that contamination varied with different batches of columns. The 16S rRNA amplified product was sequenced by using primers for the Legionella 16S rRNA gene (1) and the Sanger dideoxy chain terminator method (5), and the sequence obtained was compared with those submitted to the GenBank database by using BLAST (http://www.ncbi.nlm.nih.gov/BLAST/). The closest matches for this sequence (with 96% identity) were Legionella-like amoebal pathogen (LLAP) strains 2, 3, 6, 7, 9, and 14, Legionella lytica strain L2, and Legionella birminghamensis. The alignment of the sequences from the contaminating product and these organisms can be seen in Table 1. A PCR product was also obtained from a negative Qiagen extraction control, sequenced in the 23S-5S rRNA region (4), and submitted for identification in the same manner. Of the 312 bp of sequence submitted, only 246 bp shared any similarity with any reference species that had been submitted to the National Center for Biotechnology Information BLAST database. It was noted that no LLAP sequences for the 23S-5S rRNA region had been submitted; this may explain the poor degree of identification obtained. Alternatively, the product amplified in this region may not have been from the same source (organism) as that obtained in the 16S rRNA region. Limiting the sequence identification to the 5S rRNA region gave a 96% match with Legionella steigerwaltii (Z30463). Sequencing using eubacterial primers (3) was also attempted, but this PCR was not adequately sensitive to detect a product in the water extract. We agree with van der Zee and Crielaard (6) that the Qiagen columns are likely contaminated during production through the process of flushing with water containing Legionella spp. or LLAPs. Through this process the columns may also become contaminated with other environmental microorganisms. When using Qiagen QIAamp DNA minikit for extracting DNA for an Aspergillus PCR assay, we found that the columns and reagents were also frequently contaminated with fungal DNA (unpublished observations). Consequently, Qiagen columns at present may be unsuitable for the laboratory diagnosis of environmental microorganisms (especially those with a water habitat) and not just Legionella spp.
منابع مشابه
Qiagen DNA extraction kits for sample preparation for legionella PCR are not suitable for diagnostic purposes.
Several reports describe the use of Qiagen columns as part of a Legionella PCR (1, 2). However, workers in two laboratories in The Netherlands have found that the Qiagen columns are contaminated with Legionella species. Nucleic acid sample preparation kits are commercially available from many different suppliers. Some of the most commonly used are the silica-based gel membrane or glass fiber fi...
متن کاملHighly efficient nuclear DNA typing of the World War II skeletal remains using three new autosomal short tandem repeat amplification kits with the extended European Standard Set of loci
AIM To perform an efficiency study of three new amplification kits with the extended European Standard Set (ESS) of loci for autosomal short tandem repeat (STR) typing of skeletal remains excavated from the World War II mass graves in Slovenia. METHODS In the beginning of the 2011, we analyzed 102 bones and teeth using the PowerPlex ESX 17 System (Promega), AmpFiSTR NGM PCR Amplification Kit ...
متن کاملTraces of ATCV-1 associated with laboratory component contamination.
Yolken et al. (1) claim detection of Acanthocystis turfacea chlorella virus 1 (ATCV-1, gi119953744) in the normal human oropharyngeal viral flora and associate it with altered cognitive function. However, the reported presence of a freshwater algae virus, previously not known to infect other species, was based on a few sequence reads homologous to ATCV-1 identified with BLASTn. These reads span...
متن کاملComparison of commercial DNA preparation kits for the detection of Brucellae in tissue using quantitative real-time PCR
BACKGROUND The detection of Brucellae in tissue specimens using PCR assays is difficult because the amount of bacteria is usually low. Therefore, optimised DNA extraction methods are critical. The aim of this study was to assess the performance of commercial kits for the extraction of Brucella DNA. METHODS Five kits were evaluated using clinical specimens: QIAamp DNA Mini Kit (QIAGEN), peqGol...
متن کاملOptimization of Brucella abortus Protocols for Downstream Molecular Applications
We compared the performances of various DNA extraction kits for their ability to recover Brucella abortus strain 19 inoculated into Brucella-free bovine tissues. Tissues were homogenized in a FastPrep bead homogenizer and extracted in triplicate by using one of five kits (Qiagen DNeasy, GE Illustra, Omega Bio-tek E.Z.N.A., Quanta Extracta, and IBI Science DNA Tissue kit). Whole blood was also t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 41 7 شماره
صفحات -
تاریخ انتشار 2003