Localization of thrombomodulin in the anterior segment of the human eye.

نویسندگان

  • T Ikeda
  • H Ishii
  • T Higuchi
  • K Sato
  • Y Hayashi
  • K Ikeda
  • Y Hirabayashi
چکیده

PURPOSE To localize thrombomodulin (TM) in the anterior segment of the human eye. TM is a vascular endothelial cell surface glycoprotein that acts as a cofactor for the thrombin-catalyzed activation of the anticoagulant protease zymogen, protein C. METHODS Immunohistochemical methods were used to detect TM expression in corneal epithelial cells, the lens epithelial cells, and other cells in the anterior segment of the eye. The expression of TM was also examined in cultured human corneal epithelial cells. RESULTS TM was expressed in corneal epithelial cells, corneal endothelial cells, and nonpigmented ciliary epithelial cells, which are in direct contact with the aqueous humor. TM was also expressed in cultured corneal epithelial cells and showed cofactor activity. The amount of the antigen in the cultured corneal cells was approximately one tenth of that in human umbilical vein endothelial cells, but its specific cofactor activity (75%) was comparable to that of TM in human umbilical vein endothelial cells. The trabecular meshwork and endothelial cells lining Schlemm's canal also showed positive staining for TM. CONCLUSIONS The TM in the cells that are in contact with the aqueous humor appears to be involved in maintaining the fluidity of the aqueous humor. In contrast, TM in cells that are not in contact with the aqueous humor may function in regulating cell proliferation and/or differentiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

Purtscher’s Retinopathy in a Patient with Falling Down: A Case Report

Purpose: To report a case of Purtscher’s Retinopathy in a patient with falling down. Case Report: A 25-year-old man with no history of specific disease referred to the ophthalmology clinic of Imam Hossein Hospital 2 days after falling due to a sudden vision loss in his right eye. Best-corrected visual acuity was counting finger 1m in the right and 10/10 in the left eye and Marcus Gunn pupil was...

متن کامل

THE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY

The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...

متن کامل

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 2000