Thromboelastograph guided management of a patient requiring Abiomed biventricular support with consumptive coagulopathy.

نویسندگان

  • Darshit Atul Gandhi
  • Timothy Shrewsberry
چکیده

A 69-year-old male, who underwent cardio-pulmonary bypass surgery, required biventricular support using the Abiomed. The patient subsequently developed a consumptive coagulopathy. The thromboelastograph was used to administer NovoSeven and guide allogenic transfusions to achieve a hematocrit of greater than 30% and a platelet count greater than 100,000 per microL. Disseminated intravascular coagulation was resolved and the patient was transported to a tertiary care center within 72 hours. The Abiomed BVS 5000 provided a bridge to the native heart recovery and was successfully explanted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medical and Surgical Management of Postpartum Hemorrhage in a Woman with Factor XIII Deficiency

Factor XIII deficiency is a rare inherited coagulopathy. Factor XIII is the last clotting factor in the coagulation cascade to insure strength and stability to fibrin clots. Without this enzyme, the fibrous clot is unstable and nonresistant to fibrinolysis. Gravid women with this congenital disease are especially at risk for complications including miscarriages and hemorrhage without appropriat...

متن کامل

Localized consumptive coagulopathy.

An 87-year-old man with an extensive past medical history was admitted for evaluation of intermittent hemoptysis of 1 month’s duration. During the hospitalization, he developed a large, subcutaneous bleed (Figure 1) after venipuncture. The patient had a known, expanding thoracic aortic aneurysm (Figures 2 and 3), and laboratory studies were consistent with an intravascular, consumptive coagulop...

متن کامل

Use of thromboelastograph and factor VII for the treatment of postoperative bleeding in a pediatric patient on ECMO after cardiac surgery.

This report describes a case of possibly fatal bleeding treated successfully with an "overdose" of recombinant factor VII (rFVII; Novo7). A 3.5-year-old boy had surgery for aortic stenosis and aortic arch repair and was placed on extracorporeal membrane oxygenation (ECMO) after a prolonged cardiopulmonary bypass time (CPB); there was subsequent failure to wean from CPB because of right ventricu...

متن کامل

Use of the Abiomed BVS 5000 Ventricular Assist Device for Myocardial Support Following Left Ventricular Aneurysmectomy : Case Report

Left ventricular aneurysms (LV A) are most commonly the result of a large transmural myocardial infarction, usually in the distribution of an occluded left anterior descending coronary artery. We investigated a case at Allegheny University Hospitals, Hahnemann Division, Philadelphia, PA, involving the use of the Abiomed BVS 5000 ventricular assist device (VAD) for LV A repair. The patient was s...

متن کامل

Biventricular Circulatory Support Using 2 Axial Flow Catheters for Cardiogenic Shock Without the Need for Surgical Vascular Access.

Biventricular failure in cardiogenic shock remains a major clinical problem. Use of percutaneously delivered, acute circulatory support devices for cardiogenic shock has grown exponentially due in large part to increasing global familiarity and clinical experience demonstrating hemodynamic efficacy of these devices. Until recently, percutaneous support options for biventricular failure have bee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2011