An absorption-based surface plasmon resonance sensor applied to sodium ion sensing based on an ion-selective optode membrane.

نویسندگان

  • Kazuyoshi Kurihara
  • Kaori Nakamura
  • Etsuko Hirayama
  • Koji Suzuki
چکیده

A surface plasmon resonance (SPR) sodium ion sensor using an ion optode membrane film was experimentally and theoretically described based on an absorption-based SPR principle proposed in our previous article (Kurihara, K; Suzuki, K. AnaL Chem. 2002, 74, 696-701). The sodium ion concentrations from 10(-6) to 10(-1) have been successfully determined not only by the resonance angle diagnosis of the SPR curve but also by the minimum reflectance one. The ion optode film was plasticized poly(vinyl chloride) including a neutral sodium ionophore, a pH-sensitive cationic dye, and an anionic additive. Its optical absorption intensity changed with the sodium ion concentrations. The SPR ion sensor physically measured the complex refractive index caused by the absorption in the ion optode film. We have exhaustively investigated the experimental response behavior of the SPR curve relative to the sodium ion concentrations by comparison with numerically simulated SPR curves using a three-layer Fresnel equation including experimental values for the sodium ion optode membrane film. As predicted by the absorption-based SPR principle, the SPR curve behavior of the SPR ion sensors depended on two factors: one was the relation between the excitation frequency of the light source and the absorption maximum frequency in the ion optode film while the other was the gold metallic thickness in the Kretchmann configuration. The concept and practical theory of an absorption-based SPR sensor not only have been proved by the experimental results of the SPR sodium ion sensor but also have successfully allowed flexible ion sensing in an SPR sensor, which would be very difficult without the absorption mechanism in the ion optode film.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

متن کامل

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

Hydrogen sensing by localized surface plasmon resonance in colloidal solutions of Au-WO3-Pd

Nowadays, hydrogen has attracted significant attention as a next generation clean energy source. Hydrogen is highly flammable, so detection of hydrogen gas is required. Gold nanoparticle based localized surface plasmon resonance (LSPR) is an advanced and powerful sensing technique, which is well known for its high sensitivity to surrounding refractive index change in the local environment. We p...

متن کامل

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 24  شماره 

صفحات  -

تاریخ انتشار 2002