Rapid identification of Staphyloccocus aureus in positive-testing blood cultures by Slidex Staph Plus agglutination test.

نویسندگان

  • J J Kerremans
  • W H F Goessens
  • H A Verbrugh
  • M C Vos
چکیده

In two recent articles in the Journal of Clinical Microbiology, Qian et al. (4) and Lagace-Wiens et al. (2) describe a direct coagulase and a thermostable DNase test, respectively, for direct identification of Staphylococcus aureus from positive blood culture bottles. In a prospective study from April 2003 until February 2004, we investigated the accuracy of the Slidex Staph Plus agglutination test (bioMérieux, Marcy-l’Étoile, France) on positive blood cultures containing gram-positive cocci in clusters resembling staphylococci. This agglutination test utilizes latex particles sensitized with human fibrinogen and S. aureus-specific monoclonal antibodies. These monoclonal antibodies detect protein A by the Fc fragment of immunoglobulin G as well as different polysaccharide antigens on the bacterial cell surface. Parallel to a routine subculture on blood agar plates (Columbia III blood agar base with 5% sheep red blood cells; Becton Dickinson), 6 ml from each positive Bactec (Becton Dickinson, Sparks, MD) bottle was injected in a serum separator tube (Becton Dickinson). This tube was centrifuged at 2,000 g for 10 min. Subsequently, the supernatant was removed and a sample from the top of the separator layer containing the bacteria was taken with a sterile swab and subcultured on a blood agar plate. After incubation for a minimum of 4 h and a maximum of 6 h at 35°C with 5% CO2, growth from this blood agar plate was tested with the Slidex Staph Plus test. The following day, the same agglutination test was performed on colonies from blood agar plates routinely subcultured and incubated overnight. All agglutination-positive isolates were confirmed to be S. aureus with a probe hybridization assay (AccuProbe; Gen-Probe, San Diego, CA). A total of 249 positive blood cultures containing staphylococci were evaluated. Growth from a 4to 6-h subculture on blood agar was compared with growth from an overnight subculture. Four blood cultures yielding coagulase-negative staphylococci were excluded from the analysis due to insufficient growth in the direct assay. There were 56 agglutination-testpositive overnight cultures, of which one was negative by the probe hybridization assay. Two of these agglutination-test-positive overnight cultures were negative by the 4to 6-h test. There were 189 overnight cultures negative by the agglutination test. One blood culture was Slidex positive by the 4to 6-h test, but after overnight culture, it showed autoagglutination. The culture was, erroneously, not tested for autoagglutination, and the isolate was probe hybridization negative. The sensitivity, specificity, and positive and negative predictive values for the agglutination test culture with a short incubation period (4 to 6 h) compared with the test agglutination test with overnight culture as the reference method were 96% (95% confidence interval [CI], 87 to 99%), 99% (95% CI, 97 to 99.9%), 98% (95% CI, 89 to 99.9%), and 99% (95% CI, 96 to 99.8%), respectively. The direct Slidex Staph Plus test method is easy to perform and provides reliable same-day identification results in comparison with the reference method. The sensitivity of this agglutination method after a short period of subculture incubation is higher than that reported for direct testing by Staphaurex Plus on the bacterial pellet (23%) (5) and is also higher than that reported for the tube coagulase test (65 to 85%) (1, 4) and comparable to the sensitivities of fluorescent in situ hybridization (98%) (1, 3) and the thermostable DNase test (100%) (2). Although this technique utilized the Slidex Staph Plus test, which is considered a reliable agglutination test (6), other agglutination tests will probably have comparable results. However, differences in sensitivity and specificity can occur. These possibilities should be evaluated. The additional costs of this test are low. No specific equipment is needed except for a serum separator tube, and the procedure requires limited hands-on time. Therefore, we recommend our method for direct testing of Bactec blood culture bottles growing staphylococci.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methods for identification of Staphylococcus aureus isolates in cases of bovine mastitis.

A total of 272 staphylococcal isolates from cases of bovine mastitis (159 Staphylococcus aureus) belonging to 12 different species were identified with ID32 STAPH galleries, and 51 of them were confirmed by 16S rRNA gene (rrs) sequencing. The same isolates were examined for their hemolytic activity on sheep blood agar, DNase activity, and coagulase activity and with two rapid identification kit...

متن کامل

Performance of the chromogenic medium CHROMagar Staph Aureus and the Staphychrom coagulase test in the detection and identification of Staphylococcus aureus in clinical specimens.

CHROMagar Staph aureus (CSAM) (CHROMagar Microbiology, Paris, France) is a new chromogenic medium designed to enable detection of colonies of Staphylococcus aureus by their pink color. A total of 775 specimens were cultured in parallel on CHROMagar Staph aureus and conventional media. Among the 267 S. aureus strains recovered on at least one medium, 263 were isolated on CSAM medium (sensitivity...

متن کامل

Evaluation of various rapid agglutination methods for the identification of Staphylococcus aureus.

A latex agglutination test (SeroSTAT Staph; Scott Laboratories, Fiskeville, R.I.) and two hemagglutination tests (Staphyloslide; BBL Microbiology Systems, Cockeysville, Md.; and Hemastaph; Remel, Lenexa, Kans.) were compared with the slide coagulase (SC) and tube coagulase (TC) tests at room temperature (22 to 25 degrees C) and at 37 degrees C for the rapid identification of Staphylococcus aure...

متن کامل

Rapid detection of epidemic strains of methicillin-resistant Staphylococcus aureus.

Fifty methicillin-resistant Staphylococcus aureus (MRSA) initial isolates obtained from patients hospitalized in the orthopedic clinic of the Frankfurt University Hospital and 150 methicillin-sensitive Staphylococcus aureus (MSSA) isolates were investigated in this study to determine whether the Slidex Staph-Kit is capable of differentiating between MRSA and MSSA owing to its unique performance...

متن کامل

Evaluation of different tests for detection of Staphylococcus aureus using coagulase (coa) gene PCR as the gold standard.

A total of 288 staphylococcal specimens isolated from different clinical specimens were selected for the evaluation of tests used to detect Staphylococcus aureus. The coagulase (coa) gene PCR was preformed, which confirmed 288 specimens as S. aureus and 51 specimens as coagulase negative staphylococci (CONS). All the specimens were subjected to slide coagulase test, Slidex Staph plus test and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2008