Optic Nerve Sheath Diameter Remains Constant during Robot Assisted Laparoscopic Radical Prostatectomy

نویسندگان

  • Philip Verdonck
  • Alain F. Kalmar
  • Koen Suy
  • Thomas Geeraerts
  • Marcel Vercauteren
  • Alex Mottrie
  • Andre M. De Wolf
  • Jan F. A. Hendrickx
چکیده

BACKGROUND During robot assisted laparoscopic radical prostatectomy (RALRP), a CO2 pneumoperitoneum (CO2PP) is applied and the patient is placed in a head-down position. Intracranial pressure (ICP) is expected to acutely increase under these conditions. A non-invasive method, the optic nerve sheath diameter (ONSD) measurement, may warn us that the mechanism of protective cerebrospinal fluid (CSF) shifts becomes exhausted. METHODS After obtaining IRB approval and written informed consent, ONSD was measured by ocular ultrasound in 20 ASA I-II patients at various stages of the RALRP procedure: baseline awake, after induction, after applying the CO2PP, during head-down position, after resuming the supine position, in the postoperative anaesthesia care unit, and on day one postoperatively. Cerebral perfusion pressure (CPP) was calculated as the mean arterial (MAP) minus central venous pressure (CVP). RESULTS The ONSD did not change during head-down position, although the CVP increased from 4.2(2.5) mm Hg to 27.6(3.8) mm Hg. The CPP was decreased 70 min after assuming the head-down position until 15 min after resuming the supine position, but remained above 60 mm Hg at all times. CONCLUSION Even though ICP has been documented to increase during CO2PP and head-down positioning, we did not find any changes in ONSD during head-down position. These results indicate that intracranial blood volume does not increase up to a point that CSF migration as a compensation mechanism becomes exhausted, suggesting any increases in ICP are likely to be small.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial

BACKGROUND Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelen...

متن کامل

Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position

BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trend...

متن کامل

Current status of laparoscopic and robot-assisted nerve-sparing radical cystectomy in male patients

During radical cystectomy (RC), the neurovascular bundles are easily removed or damaged, leading to varying rates of incontinence and erectile dysfunction. The nerve-sparing technique was developed to preserve urinary and erectile function. The adoption of laparoscopic and robot-assisted technology has improved visualization and dexterity of pelvic surgeries, thus facilitate the nerve-sparing t...

متن کامل

Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45° Trendelenburg position

BACKGROUND To evaluate changes in intraocular pressure (IOP) and intracerebral pressure (ICP) reflected by the optic nerve sheath diameter (ONSD) in patients undergoing robotic-assisted laparoscopic prostatectomy (RALP) in permanent 45° steep Trendelenburg position (STP). METHODS Fifty-one patients undergoing RALP under a standardised anaesthesia. IOP was perioperatively measured in awake pat...

متن کامل

Cavernous Nerve Graft Reconstruction with a Novel Artificial Conduit during Robot-Assisted Laparoscopic Radical Prostatectomy

The interposition sural nerve graft has been attempted occasionally during radical prostatectomy for the recovery of continence and erectile function; however, nerve autograft may result in adverse events for the patient. Here, we present our initial experiences using NerbridgeTM, a novel conduit for peripheral nerve regeneration, rather than utilizing sural nerve grafting, in robot-assisted la...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014