Cold atom clock test of Lorentz invariance in the matter sector.

نویسندگان

  • Peter Wolf
  • Fréderic Chapelet
  • Sébastien Bize
  • André Clairon
چکیده

We report on a new experiment that tests for a violation of Lorentz invariance (LI), by searching for a dependence of atomic transition frequencies on the orientation of the spin of the involved states (Hughes-Drever type experiment). The atomic frequencies are measured using a laser cooled 133Cs atomic fountain clock, operating on a particular combination of Zeeman substates. We analyze the results within the framework of the Lorentz violating standard model extension (SME), where our experiment is sensitive to a largely unexplored region of the SME parameter space, corresponding to first measurements of four proton parameters and improvements by 11 and 13 orders of magnitude on the determination of four others. In spite of the attained uncertainties, and of having extended the search into a new region of the SME, we still find no indication of LI violation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Experimental Tests of Special Relativity

We review our recent Michelson-Morley (MM) and Kennedy-Thorndike (KT) experiment, which tests Lorentz invariance in the photon sector, and report first results of our ongoing atomic clock test of Lorentz invariance in the matter sector. The MM-KT experiment compares a cryogenic microwave resonator to a hydrogen maser, and has set the most stringent limit on a number of parameters in alternative...

متن کامل

Enhanced sensitivity to Lorentz invariance violations in short-range gravity experiments

Recently, first limits on putative Lorentz invariance violation coefficients in the pure gravity sector were determined by the reanalysis of short-range gravity experiments. Such experiments search for new physics at sidereal frequencies. They are not, however, designed to optimize the signal strength of a Lorentz invariance violation force; in fact the Lorentz violating signal is suppressed in...

متن کامل

ar X iv : h ep - p h / 04 07 23 2 v 2 21 J ul 2 00 4 Improved Test of Lorentz Invariance in Electrodynamics

We report new results of a test of Lorentz invariance based on the comparison of a cryogenic sapphire microwave resonator and a hydrogen maser. The experimental results are shown together with an extensive analysis of systematic effects. Previously, this experiment has set the most stringent constraint on Kennedy-Thorndike type violations of Lorentz invariance. In this work we present new data ...

متن کامل

Search for Lorentz Violation in a Short-range Gravity Experiment

Local Lorentz invariance is at the foundation of both the Standard Model of particle physics and General Relativity, but is generally poorly tested for the latter theory. Violation of Lorentz symmetry would break the isotropy of spacetime, permitting the vacuum to fill with ‘background’ fields that have a preferred direction. Interaction of the test masses in a terrestrial gravity experiment wi...

متن کامل

Testing Lorentz and CPT Invariance with Neutrinos

Neutrino experiments can be considered sensitive tools to test Lorentz and CPT invariance. Taking advantage of the great variety of neutrino experiments, including neutrino oscillations, weak decays, and astrophysical neutrinos, the generic experimental signatures of the breakdown of these fundamental symmetries in the neutrino sector are presented.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 96 6  شماره 

صفحات  -

تاریخ انتشار 2006