Feasibility of transfemoral hepatic vein/wedged portal venous pressure measurement in total artificial heart

نویسندگان

  • Ashwani Kumar Sharma
  • Jonathan Huang
  • Himabindu Vidula
  • Jeffrey Alexis
  • Juan M. Lehoux
چکیده

The development of technology and limitation of numerous ventricular assist devices has increased usage of the total artificial heart (TAH) for mechanical circulatory support. A primary important feature of TAH is that it is one of the few mechanical circulatory support devices that provides biventricular support. As the number of patients with TAH rises, spreading awareness about the device in the interventional radiology community is important.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hepatic venous pressure gradient measurement: time to learn!

Portal hypertension is a clinical syndrome defined by a pathological increase in portal pressure. The development of cirrhosis of the liver is characterized by clinical manifestations related to portal hypertension like esophageal varices, ascites, bleeding, and encephalopathy. Direct measurement of portal pressure is invasive, inconvenient, and clinically impractical. Currently, the most commo...

متن کامل

CO(2) wedged hepatic venography in the evaluation of portal hypertension.

BACKGROUND/AIMS/METHODS During hepatic vein catheterisation, in addition to measurement of hepatic venous pressure gradient (HVPG), iodine wedged retrograde portography can be easily obtained. However, it rarely allows correct visualisation of the portal vein. Recently, CO(2) has been suggested to allow better angiographic demonstration of the portal vein than iodine. In this study we investiga...

متن کامل

The relationship between intrahepatic portal systemic shunts and microsphere induced portal hypertension in the rat liver.

BACKGROUND Portal hypertension is associated with gross haemodynamic disturbances characterised by high cardiac output, low peripheral vascular resistance, increased splanchnic blood flow, and portal systemic shunting. AIMS To study the relationship between intrahepatic portal systemic shunts and microsphere induced portal hypertension in the rat liver. METHODS Different sized microspheres ...

متن کامل

Three minimally invasive methods of measuring of portal vein pressure in healthy dogs.

We compared wedged hepatic venous pressure (WHVP), splenic pulp pressure (SPP) and trans-splenic portal vein pressure (TSPVP) in healthy dogs. We found that portal blood pressure could be measured in dogs using any of these techniques. The WHVP, SPP and TSPVP were 7.8 ± 1.0, 6.2 ± 0.8 and 6.8 ± 1.2 mmHg, respectively. Measuring SPP using ultrasound is most simple and minimally invasive, and it ...

متن کامل

Non-invasive Predictors of Portal Hypertension in Patients with Hepatitis C Virus Related Hepatocellular Carcinoma.

The reference standard for portal venous pressure measurement which is clinically important for estimating the. feasibility of resection of hepatocellular carcinoma is the hepatic venous pressure gradient, which is, invasive and expqnsive. The present study evaluated the noninvasive parameters for assessment of portal hypertension in Child A patients with hepatocellular carcinoma on top of hepa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017