Diagnostic confusion? Repeat HbA1c for the diagnosis of diabetes.

نویسندگان

  • Timothy J McDonald
  • Roderick Warren
چکیده

HbA1c has been recommended as a test option for the diagnosis of diabetes by both the American Diabetes Association (1) and the World Health Organization (WHO) (2). Both organizations advised that after a result consistent with the diagnosis of diabetes ($6.5% [48 mmol/mol]), HbA1c levels should be repeated in asymptomatic patients within 2 weeks to rule out the rare occurrence of a sample being mislabelled. Consensus statements from expert bodies in the U.K. endorsed these recommendations, which were implemented locally in 2012 (3). Since adoption of HbA1c as the principal test for diabetes, we have received a steady trickle of queries about discordant HbA1c results from clinicians. In some cases, the discrepancy between two results obtained within the short repeat interval was striking. To address this issue, we aimed to determine the magnitude and nature of variation seen in HbA1c results repeated within 14 days of an initial diagnosis of diabetes. We extracted anonymized HbA1c results (analyzed on the Tosoh G8 HPLC Analyzer; Tosoh Bioscience, South San Francisco, CA; coefficient of variation 5 2.3% at 10% [86 mmol/mol]) from our laboratory information management system between April and June 2013. We identified cases where HbA1cwas used to screen for diabetes,with results of $6.5% (48 mmol/mol), and a subsequent repeat HbA1c requested within 14 days (n 5 188). We limited our analysis to uncomplicated cases of newly diagnosed type 2 diabetes, excluding patients with rapid-onset type 1 diabetes, drug-associatedhyperglycemia (e.g., glucocorticoids), and acute illness. The average interval between repeat testing was 7 days (range 1–14 days). In 63% of patients, the repeat HbA1c was lower than the first; in 20%, it was higher. The mean change in HbA1c was a fall of 0.2% (1.64 mmol/mol), with 12% of patients having a fall of at least 0.5% (5 mmol/mol) (Fig. 1). In 39% (73/188) of cases, the second HbA1c result was below the diagnostic threshold of 6.5% (48 mmol/mol). This change in HbA1c cannot be explained by analytical variation alone, at the group mean of 6.9% (52 mmol/mol) the analytical variation would account for a maximum of 6 0.08% (0.6 mmol/mol) in an individual patient. Therewas no association between change in HbA1c and initial HbA1c (r 5 20.047, P 5 0.52). Similarly, there was no association between change in HbA1c and interval between testing (r 5 0.01, P 5 0.991). Inspection of clinical records in these cases did not reveal any factors that might explain the greater variability. The results of this study indicate there is significant short-term variability of HbA1c. It is common for a repeat HbA1c to be below the threshold for diagnosis of diabetes after a first apparently diagnostic test, potentially leading to diagnostic confusion and uncertainty. The tendency for HbA1c to fall on repeat testing may reflect regression to the mean and/or genuine glycemic change over the preceding 14 days. This study cannot determine the reason for the fall in mean HbA1c. However, if regression to themean had been the main mechanism, then we would expect higher initial HbA1c to be associated with greater fall on retesting; no such association was seen. Similarly, if true change in blood glucose levels was the main mechanism, we would expect a greater fall in HbA1c with longer interval between testing; again, no such association was seen. This association may be revealed in a study of larger numbers. We believe a policy of retesting HbA1c after a single apparently diagnostic result seems to be justified, with nearly 40% of cases having a repeat test below the diagnostic threshold. Clinicians need to be aware that significant test-retest variation exists inHbA1c and is sometimesquite large.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trend of Changes in Blood Sugar and Glycated Hemoglobin in Electronic Health Records, Sari, Iran 2012- 2018

Background and purpose: High prevalence of Type 2 Diabetes Mellitus (T2DM) and its demand for regular care have resulted in a massive amount of electronic health records (EHRs). Hemoglobin A1c (HbA1c) and Fasting Blood Sugar (FBS) levels are two widely-used diagnostic measures for evaluation of diabetes care. This study aimed at assessing Family Medicine Plan (FMP) and exploring the trend of ch...

متن کامل

The diagnosis value of blood glucose combined glycosylated hemoglobin in gestational diabetes

Gestational diabetes mellitus is a common complication in gestation period, and single diagnostic test of blood glucose always results in misdiagnosis. Previous studies showed that glycosylated hemoglobin was a promising biomarker for screening, diagnosis and treatment of diabetes. Combined measurements can improve the sensitivity and specificity of diagnosis. Thus, our study aimed to explore t...

متن کامل

Can Hba1c Prove Helpful in Diagnosis of Type 2 DM in India?

Type-2 diabetic is increased manifold in recent years and India is very well considered as the diabetic capital of the world. Diabetes poses a great economic burden to the family and the nation. FBS and PPBS has always been the test of choice for diagnosis of diabetes though OGTT is considered often. But the trend of using HbA1c for diagnosis is not there in India although HbA1c is very often u...

متن کامل

HbA1c screening for new onset diabetes following acute coronary syndrome: is it a worthwhile test in clinical practice?

BACKGROUND Diabetes and pre-diabetes are prevalent in acute coronary syndrome (ACS) and relate to adverse outcomes. This study used HbA1c to screen for degrees of glucose intolerance amongst patients without known diabetes presenting with ACS. METHODS Over a 1-year period (June 2014-2015) consecutive patients admitted to a single centre cardiology unit with an initial diagnosis of ACS without...

متن کامل

Concordance of Two Diabetes Diagnostic Criteria Using Fasting Plasma Glucose and Hemoglobin A1c: The Yuport Medical Checkup Centre Study

BACKGROUND We tested the concordance of the two diagnostic criteria for diabetes using fasting plasma glucose (FPG) and hemoglobin A1c (HbA1c) by the Japan Diabetes Society (JDS) and American Diabetes Association (ADA). METHODS We used data from 7,328 subjects without known diabetes who participated in a voluntary health checkup program at least twice between 1998 and 2006, at intervals ≤ 2 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes care

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 2014