Online correction of licking-induced brain motion during two-photon imaging with a tunable lens.
نویسندگان
چکیده
Two-photon calcium imaging in awake, head-fixed animals enables the measurement of neuronal activity during behaviour. Often, licking for the retrieval of water reward is used as a measurable report of the animal's decision during reward-driven behaviour. However, licking behaviour can induce severe motion artifacts that interfere with two-photon imaging of cellular activity. Here, we describe a simple method for the online correction of licking-induced focus shifts for two-photon calcium imaging of neocortical neurons in the head-fixed mouse. We found that licking causes a stereotyped drop of neocortical tissue, shifting neurons up to 20 μm out of focus. Based on the measurement of licking with a piezo film sensor, we developed a feedback model, which provides a corrective signal for fast optical focus adjustments with an electrically tunable lens. Using online correction with this feedback model, we demonstrate a reduction of licking-related focus changes below 3 μm, minimizing motion artifact contamination of cellular calcium signals. Focus correction with a tunable lens is a simple and effective method to improve the ability to monitor neuronal activity during reward-based behaviour.
منابع مشابه
اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملFast two-layer two-photon imaging of neuronal cell populations using an electrically tunable lens
Functional two-photon Ca(2+)-imaging is a versatile tool to study the dynamics of neuronal populations in brain slices and living animals. However, population imaging is typically restricted to a single two-dimensional image plane. By introducing an electrically tunable lens into the excitation path of a two-photon microscope we were able to realize fast axial focus shifts within 15 ms. The max...
متن کاملAssessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain
Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...
متن کاملBrain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review
Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...
متن کاملNoRMCorre: An online algorithm for piecewise rigid motion correction of calcium imaging data
BACKGROUND Motion correction is a challenging pre-processing problem that arises early in the analysis pipeline of calcium imaging data sequences. The motion artifacts in two-photon microscopy recordings can be non-rigid, arising from the finite time of raster scanning and non-uniform deformations of the brain medium. NEW METHOD We introduce an algorithm for fast Non-Rigid Motion Correction (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of physiology
دوره 591 19 شماره
صفحات -
تاریخ انتشار 2013