Rescuing the obese or burned airway: are conventional training manikins adequate? A simulation study.

نویسندگان

  • T E Howes
  • C A Lobo
  • F E Kelly
  • T M Cook
چکیده

BACKGROUND Percutaneous tracheal access is required in more than 40% of major airway emergencies, and rates of failure are high among anaesthetists. Supraglottic airway management is more likely to fail in patients with obesity or neck pathology. Commercially available manikins may aid training. In this study, we modified a standard 'front of neck' manikin and evaluated anaesthetists' performance of percutaneous tracheal access. METHODS Two cricothyroidotomy training manikins were modified using sections of belly pork to simulate a morbidly obese patient and an obese patient with neck burns. An unmodified manikin was used to simulate a slim patient. Twenty consultant anaesthetists were asked to manage a 'can't intubate, can't ventilate' scenario involving each of the three manikins. Outcome measures were success using their chosen technique and time to first effective breath. RESULTS Success rates using first-choice equipment were: 'slim' manikin 100%, 'morbidly obese' manikin 60%, and 'burned obese' manikin 77%. All attempts on the 'slim' manikin succeeded within 240 s, the majority within 120 s. In attempts on the 'morbidly obese' manikin, 60% succeeded within 240 s and 20% required more than 720 s. All attempts on the 'burned obese' manikin succeeded within 180 s. CONCLUSIONS Significantly greater technical difficulty was experienced with our 'morbidly obese' manikin compared with the unmodified manikin. Failure rates and times to completion were considerably more consistent with real-life reports. Modifying a standard manikin to simulate an obese patient is likely to better prepare anaesthetists for this challenging situation. Development of a commercial manikin with such properties would be of value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Three Different Supraglottic Airway Devices in Neonatal Airway Training during Resuscitation Simulation

Objective: The aim of this study was to compare the success rates for insertion using the laryngeal mask, laryngeal tube, and I-gel supraglottic airway devices in a neonatal airway manikin during a resuscitation simulation course. Methods: Three groups of health care professionals were given a brief supervised training in using the devices. For each participant the positioning of each device wa...

متن کامل

Paediatric difficult airway management: what every anaesthetist should know!

Anaesth 2015; 114: 297–306 18. Natt BS, Malo J, Hypes CD, Sakles JC, Mosier JM. Strategies to improve first attempt success at intubation in critically ill patients. Br J Anaesth 2016; 117(Suppl. 1): i60–i68 19. Mercer SJ, Jones CP, Bridge M, Clitheroe E, Morton B, Groom P. Systematic review of the anaesthetic management of noniatrogenic acute adult airway trauma. Br J Anaesth 2016; 117 (Suppl....

متن کامل

Efficacy of acute care health care providers in cardiopulmonary resuscitation compressions in normal and obese adult simulation manikins.

Annually, over 350,000 persons require cardiopulmonary resuscitation (CPR), either in or outside of the hospital. With obesity a rising health issue in the United States, concerns exist regarding the efficacy of quality compressions for CPR in obese patients. The aims of this study were to determine if the compressions for three adult simulation manikins (normal, obese, and morbidly obese) met ...

متن کامل

Advanced airway management simulation training in medical education: a systematic review and meta-analysis.

OBJECTIVE To perform a systematic review and meta-analysis of the literature on teaching airway management using technology-enhanced simulation. DATA SOURCES We searched MEDLINE, EMBASE, CINAHL, PsycINFO, ERIC, Web of Science, and Scopus for eligible articles through May 11, 2011. STUDY SELECTION Observational or controlled trials instructing medical professionals in direct or fiberoptic in...

متن کامل

Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers.

BACKGROUND Human patient simulators and airway training manikins are widely used to train airway management skills to medical professionals. Furthermore, these patient simulators are employed as standardized "patients" to evaluate airway devices. However, little is known about how realistic these patient simulators and airway-training manikins really are. This trial aimed to evaluate the upper ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 114 1  شماره 

صفحات  -

تاریخ انتشار 2015