Quantitative investigation of linear arbitrary polarization in an APPLE-II undulator
نویسندگان
چکیده
Insertion devices are utilized at synchrotron radiation facilities around the world for their capability to provide a high-brilliance X-ray beam. APPLE-II type undulators are especially important for their capacity to switch between a variety of photon beam polarization states. A high-precision soft X-ray polarimeter has been used to investigate the polarization calibration of an APPLE-II undulator (period length λu = 64 mm) installed on beamline I06 at Diamond Light Source. Systematic measurement of the beam polarization state at a range of linear arbitrary angles has been compared with the expected result for a given set of undulator gap and row phase parameters calculated from theory. Determination of the corresponding Stokes-Poincaré parameters from the measured data reveals a discrepancy between the two. The limited number of energy/polarization combinations included in the undulator calibration tables necessitates the use of interpolated values for the missing points which is expected to contribute to the discrepancy. However, by modifying the orbit of the electron beam through the undulator by at least 160 µm it has been found that for certain linear polarizations the discrepancies can be corrected. Overall, it is suggested that complete correction of the Stokes-Poincaré parameters for all linear angles would require alteration of both these aspects.
منابع مشابه
Investigation of the polarization state of dual APPLE-II undulators
The use of an APPLE II undulator is extremely important for providing a high-brilliance X-ray beam with the capability to switch between various photon beam polarization states. A high-precision soft X-ray polarimeter has been used to systematically investigate the polarization characteristics of the two helical APPLE II undulators installed on beamline I06 at Diamond Light Source. A simple dat...
متن کاملDelta Undulator for Cornell Energy Recovery Linac
In anticipation of a new era of synchrotron radiation sources based on Energy Recovery Linac techniques we designed, built and tested a short undulator magnet prototype whose features make optimum use of the unique conditions expected in these facilities. The prototype has pure permanent magnet (PPM) structure with 24mm period, 5mm diameter round gap and is 30cm long. In comparison with convent...
متن کاملConceptual Design of a Hybrid-Type Elliptically Polarizing Undulator*
There are several means of generating circularly polarized light. The use of an electromagnetic helical device is very popular for the experiments using lower photon energy radiation. An advantage of the electromagnetic device is the capability of fast switching of polarization. However, due to its complicated structure and a limited maximum current, construction of a shorter period (< 100 mm) ...
متن کاملPolarization Analysis of Nonlinear Harmonic Radiation in a Crossed-Planar Undulator
There is growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. The crossed-planar undulator, which was first proposed by Kim, could achieve rapid polarization control in synchrotron radiation sources and free electron lasers (FELs) through the manipulation of a phase shifter. Recently, a statistical analysis shows that a polarizatio...
متن کاملMagnetic Design of an Apple Iii Undulator for Swissfel
For the SwissFEL at PSI beside the hard x-ray beamline to start with a soft x-ray line is planned to cover the wavelength between 0.7 and 7.0nm. For full control of the polarization of the FEL light, APPLE undulators are forseen. In this paper the design of these devices is introduced and the preliminary magnetic configuration together with the optimization strategy is presented in details.