Trabecular Metal Acetabular Components Reduce the Risk of Revision Following Primary Total Hip Arthroplasty: A Propensity Score Matched Study From the National Joint Registry for England and Wales.

نویسندگان

  • Gulraj S Matharu
  • Andrew Judge
  • David W Murray
  • Hemant G Pandit
چکیده

BACKGROUND Trabecular metal (TM)-coated acetabular components are increasingly used in both primary and revision total hip arthroplasty (THA). However, previous studies assessing TM acetabular components have been small single-center cohorts with most lacking a control group. We compared revision rates following primary THA between TM and non-TM-coated acetabular components. METHODS A retrospective observational study was performed using National Joint Registry data, which included primary THAs with the same cementless acetabular component (either TM or non-TM coated). TM and non-TM implants were matched for multiple potential confounding factors using propensity scores. Outcomes following primary THA (revision for all-cause acetabular indications, aseptic acetabular loosening, and infection) were compared between matched groups using competing risk regression analysis. RESULTS In 18,200 primary THAs (9100 TM and 9100 non-TM), the overall prevalence of acetabular revision, revision for aseptic acetabular loosening, and septic revision was 1.2%, 0.13%, and 0.59% respectively. Five-year revision rates for all-causes (1.0% vs 1.8%, sub-hazard ratio [SHR] 0.57, 95% confidence interval [CI] 0.43-0.76, P < .001), aseptic acetabular loosening (0.1% vs 0.2%, SHR 0.35, 95% CI 0.14-0.90, P = .029), and infection (0.5% vs 0.9%, SHR 0.51, 95% CI 0.34-0.76, P = .001) were all lower in TM compared with non-TM implants. CONCLUSION Following primary THA, TM-coated acetabular implants had a reduced risk of both aseptic and septic revision compared with non-TM implants. Although absolute differences in revision risk were small, they may be clinically significant if TM designs were implanted in more complex cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Validation of primary metal-on-metal hip arthroplasties on the National Joint Registry for England, Wales and Northern Ireland using data from the London Implant Retrieval Centre

Bone Joint J 2015;97-B:10–18. Received 11 October 2014; Accepted after revision 7 November 2014 Arthroplasty registries are important for the surveillance of joint replacements and the evaluation of outcome. Independent validation of registry data ensures high quality. The ability for orthopaedic implant retrieval centres to validate registry data is not known. We analysed data from the Nationa...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

ANAlysis oF 185 RevisioNs FRoM tHe NAtioNAl JoiNt RegistRy FoR eNglAND AND WAles

vol. 6, No. 7, July 2017 405 Article focus „ Few studies have assessed the outcomes following non-metal-on-metal hip arthroplasty (non-MoMHA) revision surgery performed for adverse reactions to metal debris (ARMD), despite this clinical problem being increasingly reported worldwide. outcomes following revision surgery performed for adverse reactions to metal debris in non-metal-on-metal hip art...

متن کامل

Poor outcome of revised resurfacing hip arthroplasty

BACKGROUND AND PURPOSE Recent years have seen a rapid increase in the use of resurfacing hip arthroplasty despite the lack of literature on the long-term outcome. In particular, there is little evidence regarding the outcome of revisions of primary resurfacing. The purpose of this analysis was to examine the survivorship of primary resurfacing hip arthroplasties that have been revised. PATIEN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 85 1  شماره 

صفحات  -

تاریخ انتشار 2003