Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty

نویسندگان

  • Mikkel Rathsach Andersen
  • Nikolaj Winther
  • Thomas Lind
  • Henrik SchrøDer
  • Gunnar Flivik
  • Michael Mørk Petersen
چکیده

Background and purpose - Backside wear of the polyethylene insert in total knee arthroplasty (TKA) can produce clinically significant levels of polyethylene debris, which can lead to loosening of the tibial component. Loosening due to polyethylene debris could theoretically be reduced in tibial components of monoblock polyethylene design, as there is no backside wear. We investigated the effect of 2 different tibial component designs, monoblock and modular polyethylene, on migration of the tibial component in uncemented TKA. Patients and methods - In this randomized study, 53 patients (mean age 61 years), 32 in the monoblock group and 33 in the modular group, were followed for 2 years. Radiostereometric analysis (RSA) was done postoperatively after weight bearing and after 3, 6, 12, and 24 months. The primary endpoint of the study was comparison of the tibial component migration (expressed as maximum total point motion (MTPM)) of the 2 different implant designs. Results - We did not find any statistically significant difference in MTPM between the groups at 3 months (p = 0.2) or at 6 months (p = 0.1), but at 12 and 24 months of follow-up there was a significant difference in MTPM of 0.36 mm (p = 0.02) and 0.42 mm (p = 0.02) between groups, with the highest amount of migration (1.0 mm) in the modular group. The difference in continuous migration (MTPM from 12 and 24 months) between the groups was 0.096 mm (p = 0.5), and when comparing MTPM from 3-24 months, the difference between the groups was 0.23 mm (p = 0.07). Interpretation - In both study groups, we found the early migration pattern expected, with a relatively high initial amount of migration from operation to 3 months of follow-up, followed by stabilization of the implant with little migration thereafter. However, the modular implants had a statistically significantly higher degree of migration compared to the monoblock. We believe that the greater stiffness of the modular implants was the main reason for the difference in migration, but an initial creep in the polyethylene metal-back locking mechanism of the modular group could also be a possible explanation for the observed difference in migration between the 2 study groups.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Survival of uncemented acetabular monoblock cups

BACKGROUND AND PURPOSE Monoblock acetabular cups represent a subtype of uncemented cups with the polyethylene liner molded into a metal shell, thus eliminating-or at least minimizing-potential backside wear. We hypothesized that the use of monoblock cups could reduce the incidence of osteolysis and aseptic loosening, and thus improve survival compared to modular designs. PATIENTS AND METHODS ...

متن کامل

Monoblock all-polyethylene tibial components have a lower risk of early revision than metal-backed modular components

BACKGROUND AND PURPOSE With younger patients seeking reconstructions and the activity-based demands placed on the arthroplasty construct, consideration of the role that implant characteristics play in arthroplasty longevity is warranted. We therefore evaluated the risk of early revision for a monoblock all-polyethylene tibial component compared to a metal-backed modular tibial construct with th...

متن کامل

Treatment for Wear and Osteolysis in Well-Fixed Uncemented TKR

Background. Traditionally, osteolysis around total knee replacements (TKRs) is treated with complete revision. In certain subsets, polyethylene insert exchange and bone grafting may be applicable. This study reports the clinical outcomes for selective bone grafting in patients with osteolysis without complete revision of the TKR. Methods. This retrospective study analyzes 10 TKRs (9 patients, 6...

متن کامل

Paresis of the Peroneal Nerve: A Rare But Severe Long-term Complication of Polyethylene Wear in Knee Arthroplasty.

One of the most important limiting factors in the long-term success of total knee arthroplasty is polyethylene wear. Particles of the polyethylene inserts have been shown to elicit a foreign body response, which produces bone resorption and osteolysis, ultimately leading to loosening and component failure. The authors report on a case of an elderly patient who underwent a total knee arthroplast...

متن کامل

Bilateral fatigue fracture of the femoral components in a cruciate-retaining cementless total knee prosthesis.

This article reports a case of bilateral fatigue fracture of the femoral components in a cruciate-retaining uncemented total knee arthroplasty (TKA). A 75-year-old woman (height, 158 cm; weight, 72 kg; body mass index, 29.2) had undergone one-stage bilateral TKA for osteoarthritis 11 years previously at the author's institution. Surgery was performed using an uncemented Flexible Nichidai Knee. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2016